Network Working Group S. Waldbusser
Request for Comments: 2021 INS
Category: Standards Track January 1997
Remote Network Monitoring Management Information Base
Version 2
using SMIv2
Status of this Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Abstract
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in TCP/IP-based internets.
In particular, it defines objects for managing remote network
monitoring devices.
Table of Contents
1 The Network Management Framework ...................... 2
2 Overview .............................................. 2
2.1 Remote Network Management Goals ..................... 3
2.2 Structure of MIB .................................... 5
3 Control of Remote Network Monitoring Devices .......... 6
3.1 Resource Sharing Among Multiple Management Sta-
tions .............................................. 7
3.2 Row Addition Among Multiple Management Stations ..... 9
4 Conventions ........................................... 10
5 RMON 2 Conventions .................................... 10
5.1 Usage of the term Application Level ................. 10
5.2 Protocol Directory and Limited Extensibility ........ 11
5.3 Errors in packets ................................... 11
6 Definitions ........................................... 12
7 Security Considerations ............................... 122
8 Appendix - TimeFilter Implementation Notes ........... 123
9 Acknowledgments ...................................... 129
10 References ........................................... 129
11 Author's Address...................................... 130
Waldbusser Standards Track [Page 1]
RFC 2021 Remote Network Monitoring MIB January 1997
1. The Network Management Framework
The Internet-standard Network Management Framework consists of three
components. They are:
RFC 1902 [1] which defines the SMI, the mechanisms used for
describing and naming objects for the purpose of management.
RFC 1213, STD 17, [3] which defines MIB-II, the core set of
managed objects for the Internet suite of protocols.
RFC 1905 [4] which defines the SNMP, the protocol used for
network access to managed objects.
The Framework permits new objects to be defined for the purpose of
experimentation and evaluation.
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. Within a given MIB module,
objects are defined using the SMI's OBJECT-TYPE macro. At a minimum,
each object has a name, a syntax, an access-level, and an
implementation-status.
The name is an object identifier, an administratively assigned name,
which specifies an object type. The object type together with an
object instance serves to uniquely identify a specific instantiation
of the object. For human convenience, we often use a textual string,
termed the object descriptor, to also refer to the object type.
The syntax of an object type defines the abstract data structure
corresponding to that object type. The ASN.1 [6] language is used
for this purpose. However, RFC 1902 purposely restricts the ASN.1
constructs which may be used. These restrictions are explicitly made
for simplicity.
The access-level of an object type defines whether it makes "protocol
sense" to read and/or write the value of an instance of the object
type. (This access-level is independent of any administrative
authorization policy.)
The implementation-status of an object type indicates whether the
object is mandatory, optional, obsolete, or deprecated.
2. Overview
This document continues the architecture created in the RMON MIB [RFC
1757] by providing a major feature upgrade, primarily by providing
RMON analysis up to the application layer.
Waldbusser Standards Track [Page 2]
RFC 2021 Remote Network Monitoring MIB January 1997
Remote network monitoring devices, often called monitors or probes,
are instruments that exist for the purpose of managing a network.
Often these remote probes are stand-alone devices and devote
significant internal resources for the sole purpose of managing a
network. An organization may employ many of these devices, one per
network segment, to manage its internet. In addition, these devices
may be used for a network management service provider to access a
client network, often geographically remote.
The objects defined in this document are intended as an interface
between an RMON agent and an RMON management application and are not
intended for direct manipulation by humans. While some users may
tolerate the direct display of some of these objects, few will
tolerate the complexity of manually manipulating objects to
accomplish row creation. These functions should be handled by the
management application.
2.1. Remote Network Management Goals
o Offline Operation
There are sometimes conditions when a management
station will not be in constant contact with its
remote monitoring devices. This is sometimes by
design in an attempt to lower communications costs
(especially when communicating over a WAN or
dialup link), or by accident as network failures
affect the communications between the management
station and the probe.
For this reason, this MIB allows a probe to be
configured to perform diagnostics and to collect
statistics continuously, even when communication with
the management station may not be possible or
efficient. The probe may then attempt to notify
the management station when an exceptional condition
occurs. Thus, even in circumstances where
communication between management station and probe is
not continuous, fault, performance, and configuration
information may be continuously accumulated and
communicated to the management station conveniently
and efficiently.
Waldbusser Standards Track [Page 3]
RFC 2021 Remote Network Monitoring MIB January 1997
o Proactive Monitoring
Given the resources available on the monitor, it
is potentially helpful for it continuously to run
diagnostics and to log network performance. The
monitor is always available at the onset of any
failure. It can notify the management station of the
failure and can store historical statistical
information about the failure. This historical
information can be played back by the management
station in an attempt to perform further diagnosis
into the cause of the problem.
o Problem Detection and Reporting
The monitor can be configured to recognize
conditions, most notably error conditions, and
continuously to check for them. When one of these
conditions occurs, the event may be logged, and
management stations may be notified in a number of
ways.
o Value Added Data
Because a remote monitoring device represents a
network resource dedicated exclusively to network
management functions, and because it is located
directly on the monitored portion of the network, the
remote network monitoring device has the opportunity
to add significant value to the data it collects.
For instance, by highlighting those hosts on the
network that generate the most traffic or errors, the
probe can give the management station precisely the
information it needs to solve a class of problems.
o Multiple Managers
An organization may have multiple management stations
for different units of the organization, for different
functions (e.g. engineering and operations), and in an
attempt to provide disaster recovery. Because
environments with multiple management stations are
common, the remote network monitoring device has to
deal with more than own management station,
potentially using its resources concurrently.
Waldbusser Standards Track [Page 4]
RFC 2021 Remote Network Monitoring MIB January 1997
2.2. Structure of MIB
The objects are arranged into the following groups:
- protocol directory
- protocol distribution
- address mapping
- network layer host
- network layer matrix
- application layer host
- application layer matrix
- user history
- probe configuration
These groups are the basic units of conformance. If a remote
monitoring device implements a group, then it must implement all
objects in that group. For example, a managed agent that implements
the network layer matrix group must implement the nlMatrixSDTable and
the nlMatrixDSTable.
Implementations of this MIB must also implement the system and
interfaces group of MIB-II [3]. MIB-II may also mandate the
implementation of additional groups.
These groups are defined to provide a means of assigning object
identifiers, and to provide a method for managed agents to know which
objects they must implement.
This document also contains enhancements to tables defined in the
RMON MIB [RFC 1757]. These enhancements include:
1) Adding the DroppedFrames and LastCreateTime
conventions to each table defined in the RMON MIB.
2) Augmenting the RMON filter table with a mechanism
that allows filtering based on an offset from the
beginning of a particular protocol, even if the
protocol headers are variable length.
Waldbusser Standards Track [Page 5]
RFC 2021 Remote Network Monitoring MIB January 1997
3) Augmenting the RMON filter and capture status bits
with additional bits for WAN media and generic media.
These bits are defined here as:
Bit Definition
6 For WAN media, this bit is set for packets
coming from one direction and cleared for
packets coming from the other direction.
It is an implementation specific matter
as to which bit is assigned to which
direction, but it must be consistent for
all packets received by the agent, and if
the agent knows which end of the link is
"local" and which end is "network", the bit
should be set for packets from the "local"
side and should be cleared for packets from
the "network" side.
7 For any media, this bit is set for any packet
with a physical layer error. This bit may be
set in addition to other media-specific bits
that denote the same condition.
8 For any media, this bit is set for any packet
that is too short for the media. This bit may
be set in addition to other media-specific
bits that denote the same condition.
9 For any media, this bit is set for any packet
that is too long for the media. This bit may
be set in addition to other media-specific bits
that denote the same condition.
These enhancements are implemented by RMON-2 probes that also
implement RMON and do not add any requirements to probes that are
compliant to just RMON.
3. Control of Remote Network Monitoring Devices
Due to the complex nature of the available functions in these
devices, the functions often need user configuration. In many cases,
the function requires parameters to be set up for a data collection
operation. The operation can proceed only after these parameters are
fully set up.
Many functional groups in this MIB have one or more tables in which
to set up control parameters, and one or more data tables in which to
place the results of the operation. The control tables are typically
read/write in nature, while the data tables are typically read/only.
Waldbusser Standards Track [Page 6]
RFC 2021 Remote Network Monitoring MIB January 1997
Because the parameters in the control table often describe resulting
data in the data table, many of the parameters can be modified only
when the control entry is not active. Thus, the method for modifying
these parameters is to de-activate the entry, perform the SNMP Set
operations to modify the entry, and then re-activate the entry.
Deleting the control entry causes the deletion of any associated data
entries, which also gives a convenient method for reclaiming the
resources used by the associated data.
Some objects in this MIB provide a mechanism to execute an action on
the remote monitoring device. These objects may execute an action as
a result of a change in the state of the object. For those objects
in this MIB, a request to set an object to the same value as it
currently holds would thus cause no action to occur.
To facilitate control by multiple managers, resources have to be
shared among the managers. These resources are typically the memory
and computation resources that a function requires.
3.1. Resource Sharing Among Multiple Management Stations
When multiple management stations wish to use functions that compete
for a finite amount of resources on a device, a method to facilitate
this sharing of resources is required. Potential conflicts include:
o Two management stations wish to simultaneously use
resources that together would exceed the capability of
the device.
o A management station uses a significant amount of
resources for a long period of time.
o A management station uses resources and then crashes,
forgetting to free the resources so others may
use them.
The OwnerString mechanism is provided for each management station
initiated function in this MIB to avoid these conflicts and to help
resolve them when they occur. Each function has a label identifying
the initiator (owner) of the function. This label is set by the
initiator to provide for the following possibilities:
o A management station may recognize resources it owns
and no longer needs.
o A network operator can find the management station that
owns the resource and negotiate for it to be freed.
o A network operator may decide to unilaterally free
resources another network operator has reserved.
Waldbusser Standards Track [Page 7]
RFC 2021 Remote Network Monitoring MIB January 1997
o Upon initialization, a management station may recognize
resources it had reserved in the past. With this
information it may free the resources if it no longer
needs them.
Management stations and probes should support any format of the owner
string dictated by the local policy of the organization. It is
suggested that this name contain one or more of the following: IP
address, management station name, network manager's name, location,
or phone number. This information will help users to share the
resources more effectively.
There is often default functionality that the device or the
administrator of the probe (often the network administrator) wishes
to set up. The resources associated with this functionality are then
owned by the device itself or by the network administrator, and are
intended to be long-lived. In this case, the device or the
administrator will set the relevant owner object to a string starting
with 'monitor'. Indiscriminate modification of the monitor-owned
configuration by network management stations is discouraged. In
fact, a network management station should only modify these objects
under the direction of the administrator of the probe.
Resources on a probe are scarce and are typically allocated when
control rows are created by an application. Since many applications
may be using a probe simultaneously, indiscriminate allocation of
resources to particular applications is very likely to cause resource
shortages in the probe.
When a network management station wishes to utilize a function in a
monitor, it is encouraged to first scan the control table of that
function to find an instance with similar parameters to share. This
is especially true for those instances owned by the monitor, which
can be assumed to change infrequently. If a management station
decides to share an instance owned by another management station, it
should understand that the management station that owns the instance
may indiscriminately modify or delete it.
It should be noted that a management application should have the most
trust in a monitor-owned row because it should be changed very
infrequently. A row owned by the management application is less
long-lived because a network administrator is more likely to re-
assign resources from a row that is in use by one user than from a
monitor-owned row that is potentially in use by many users. A row
owned by another application would be even less long-lived because
the other application may delete or modify that row completely at its
discretion.
Waldbusser Standards Track [Page 8]
RFC 2021 Remote Network Monitoring MIB January 1997
3.2. Row Addition Among Multiple Management Stations
The addition of new rows is achieved using the RowStatus method
described in RFC 1903 [2]. In this MIB, rows are often added to a
table in order to configure a function. This configuration usually
involves parameters that control the operation of the function. The
agent must check these parameters to make sure they are appropriate
given restrictions defined in this MIB as well as any implementation
specific restrictions such as lack of resources. The agent
implementor may be confused as to when to check these parameters and
when to signal to the management station that the parameters are
invalid. There are two opportunities:
o When the management station sets each parameter object.
o When the management station sets the row status object
to active.
If the latter is chosen, it would be unclear to the management
station which of the several parameters was invalid and caused the
badValue error to be emitted. Thus, wherever possible, the
implementor should choose the former as it will provide more
information to the management station.
A problem can arise when multiple management stations attempt to set
configuration information simultaneously using SNMP. When this
involves the addition of a new conceptual row in the same control
table, the managers may collide, attempting to create the same entry.
To guard against these collisions, each such control entry contains a
status object with special semantics that help to arbitrate among the
managers. If an attempt is made with the row addition mechanism to
create such a status object and that object already exists, an error
is returned. When more than one manager simultaneously attempts to
create the same conceptual row, only the first will succeed. The
others will receive an error.
In the RMON MIB [RFC 1757], the EntryStatus textual convention was
introduced to provide this mutual exclusion function. Since then,
this function was added to the SNMP framework as the RowStatus
textual convention. The RowStatus textual convention is used for the
definition of all new tables.
When a manager wishes to create a new control entry, it needs to
choose an index for that row. It may choose this index in a variety
of ways, hopefully minimizing the chances that the index is in use by
another manager. If the index is in use, the mechanism mentioned
previously will guard against collisions. Examples of schemes to
choose index values include random selection or scanning the control
Waldbusser Standards Track [Page 9]
RFC 2021 Remote Network Monitoring MIB January 1997
table looking for the first unused index. Because index values may
be any valid value in the range and they are chosen by the manager,
the agent must allow a row to be created with any unused index value
if it has the resources to create a new row.
Some tables in this MIB reference other tables within this MIB. When
creating or deleting entries in these tables, it is generally
allowable for dangling references to exist. There is no defined
order for creating or deleting entries in these tables.
4. Conventions
The following conventions are used throughout the RMON MIB and its
companion documents.
Good Packets
Good packets are error-free packets that have a valid frame length.
For example, on Ethernet, good packets are error-free packets that
are between 64 octets long and 1518 octets long. They follow the
form defined in IEEE 802.3 section 3.2.all.
Bad Packets
Bad packets are packets that have proper framing and are therefore
recognized as packets, but contain errors within the packet or have
an invalid length. For example, on Ethernet, bad packets have a
valid preamble and SFD, but have a bad CRC, or are either shorter
than 64 octets or longer than 1518 octets.
5. RMON 2 Conventions
The following practices and conventions are introduced in the RMON 2
MIB.
5.1. Usage of the term Application Level
There are many cases in this MIB where the term Application Level is
used to describe a class of protocols or a capability. This does not
typically mean a protocol that is an OSI Layer 7 protocol. Rather,
it is used to identify a class of protocols that is not limited to
MAC-layer and network-layer protocols, but can also include
transport, session, presentation, and application-layer protocols.
Waldbusser Standards Track [Page 10]
RFC 2021 Remote Network Monitoring MIB January 1997
5.2. Protocol Directory and Limited Extensibility
Every RMON 2 implementation will have the capability to parse certain
types of packets and identify their protocol type at multiple levels,
The protocol directory presents an inventory of those protocol types
the probe is capable of monitoring, and allows the addition,
deletion, and configuration of protocol types in this list.
One concept deserves special attention: the "limited extensibility"
of the protocol directory table. The RMON 2 model is that protocols
are detected by static software that has been written at
implementation time. Therefore, as a matter of configuration, an
implementation does not have the ability to suddenly learn how to
parse new packet types. However, an implementation may be written
such that the software knows where the demultiplexing field is for a
particular protocol, and can be written in such a way that the
decoding of the next layer up is table-driven. This works when the
code has been written to accomodate it and can be extended no more
than one level higher. This extensibility is called "limited
extensibility" to highlight these limitations. However, this can be
a very useful tool.
For example, suppose that an implementation has C code that
understands how to decode IP packets on any of several ethernet
encapsulations, and also knows how to interpret the IP protocol field
to recognize UDP packets and how to decode the UDP port number
fields. That implementation may be table- driven so that among the
many different UDP port numbers possible, it is configured to
recognize 161 as SNMP, port 53 as DNS, and port 69 as TFTP. The
limited extensibility of the protocol directory table would allow an
SNMP operation to create an entry that would create an additional
table mapping for UDP that would recognize UDP port 123 as NTP and
begin counting such packets.
This limited extensibility is an option that an implementation can
choose to allow or disallow for any protocol that has child
protocols.
5.3. Errors in packets
Packets with link-level errors are not counted anywhere in this MIB
because most variables in this MIB requires the decoding of the
contents of the packet, which is meaningless if there is a link-level
error.
Packets in which protocol errors are detected are counted for all
protocols below the layer in which the error was encountered. The
implication of this is that packets in which errors are detected at
Waldbusser Standards Track [Page 11]
RFC 2021 Remote Network Monitoring MIB January 1997
the network-layer are not counted anywhere in this MIB, while packets
with errors detected at the transport layer may have network-layer
statistics counted.
6. Definitions
RMON2-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32,
Gauge32, IpAddress, TimeTicks FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus, DisplayString, TimeStamp
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
mib-2, ifIndex FROM RFC1213-MIB
OwnerString, statistics, history, hosts,
matrix, filter, etherStatsEntry, historyControlEntry,
hostControlEntry, matrixControlEntry, filterEntry,
channelEntry FROM RMON-MIB
tokenRing, tokenRingMLStatsEntry, tokenRingPStatsEntry,
ringStationControlEntry, sourceRoutingStatsEntry
FROM TOKEN-RING-RMON-MIB;
-- Remote Network Monitoring MIB
rmon MODULE-IDENTITY
LAST-UPDATED "9605270000Z"
ORGANIZATION "IETF RMON MIB Working Group"
CONTACT-INFO
"Steve Waldbusser (WG Editor)
Postal: International Network Services
650 Castro Street, Suite 260
Mountain View, CA 94041
Phone: +1 415 254 4251
Email: waldbusser@ins.com
Andy Bierman (WG Chair)
Phone: +1 805 648 2028
Email: abierman@west.net"
DESCRIPTION
"The MIB module for managing remote monitoring
device implementations. This MIB module
augments the original RMON MIB as specified in
RFC 1757."
::= { mib-2 16 }
-- { rmon 1 } through { rmon 10 } are defined in RMON and
-- the Token Ring RMON MIB [RFC 1513]
Waldbusser Standards Track [Page 12]
RFC 2021 Remote Network Monitoring MIB January 1997
protocolDir OBJECT IDENTIFIER ::= { rmon 11 }
protocolDist OBJECT IDENTIFIER ::= { rmon 12 }
addressMap OBJECT IDENTIFIER ::= { rmon 13 }
nlHost OBJECT IDENTIFIER ::= { rmon 14 }
nlMatrix OBJECT IDENTIFIER ::= { rmon 15 }
alHost OBJECT IDENTIFIER ::= { rmon 16 }
alMatrix OBJECT IDENTIFIER ::= { rmon 17 }
usrHistory OBJECT IDENTIFIER ::= { rmon 18 }
probeConfig OBJECT IDENTIFIER ::= { rmon 19 }
rmonConformance OBJECT IDENTIFIER ::= { rmon 20 }
-- Textual Conventions
ZeroBasedCounter32 ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This TC describes an object which counts events with the
following semantics: objects of this type will be set to
zero(0) on creation and will thereafter count appropriate
events, wrapping back to zero(0) when the value 2^32 is
reached.
Provided that an application discovers the new object within
the minimum time to wrap it can use the initial value as a
delta since it last polled the table of which this object is
part. It is important for a management station to be aware of
this minimum time and the actual time between polls, and to
discard data if the actual time is too long or there is no
defined minimum time.
Typically this TC is used in tables where the INDEX space is
constantly changing and/or the TimeFilter mechanism is in use."
SYNTAX Gauge32
LastCreateTime ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This TC describes an object that stores the last time its
entry was created.
This can be used for polling applications to determine that an
entry has been deleted and re-created between polls, causing
an otherwise undetectable discontinuity in the data."
SYNTAX TimeStamp
TimeFilter ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
Waldbusser Standards Track [Page 13]
RFC 2021 Remote Network Monitoring MIB January 1997
"To be used for the index to a table. Allows an application
to download only those rows changed since a particular time.
A row is considered changed if the value of any object in the
row changes or if the row is created or deleted.
When sysUpTime is equal to zero, this table shall be empty.
One entry exists for each past value of sysUpTime, except that
the whole table is purged should sysUpTime wrap.
As this basic row is updated new conceptual rows are created
(which still share the now updated object values with all
other instances). The number of instances which are created
is determined by the value of sysUpTime at which the basic row
was last updated. One instance will exist for each value of
sysUpTime at the last update time for the row. A new
timeMark instance is created for each new sysUpTime value.
Each new conceptual row will be associated with the timeMark
instance which was created at the value of sysUpTime with
which the conceptual row is to be associated.
By definition all conceptual rows were updated at or after
time zero and so at least one conceptual row (associated with
timeMark.0) must exist for each underlying (basic) row.
See the appendix for further discussion of this variable.
Consider the following fooTable:
fooTable ...
INDEX { fooTimeMark, fooIndex }
FooEntry {
fooTimeMark TimeFilter
fooIndex INTEGER,
fooCounts Counter
}
Should there be two basic rows in this table (fooIndex == 1,
fooIndex == 2) and row 1 was updated most recently at time 6,
while row 2 was updated most recently at time 8, and both rows
had been updated on several earlier occasions such that the
current values were 5 and 9 respectively then the following
fooCounts instances would exist.
fooCounts.0.1 5
fooCounts.0.2 9
fooCounts.1.1 5
Waldbusser Standards Track [Page 14]
RFC 2021 Remote Network Monitoring MIB January 1997
fooCounts.1.2 9
fooCounts.2.1 5
fooCounts.2.2 9
fooCounts.3.1 5
fooCounts.3.2 9
fooCounts.4.1 5
fooCounts.4.2 9
fooCounts.5.1 5
fooCounts.5.2 9
fooCounts.6.1 5
fooCounts.6.2 9
fooCounts.7.2 9 -- note that row 1 doesn't exist for
fooCounts.8.2 9 -- times 7 and 8"
SYNTAX TimeTicks
DataSource ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Identifies the source of the data that the associated
function is configured to analyze. This source can be any
interface on this device.
In order to identify a particular interface, this
object shall identify the instance of the ifIndex
object, defined in [3,5], for the desired interface.
For example, if an entry were to receive data from
interface #1, this object would be set to ifIndex.1."
SYNTAX OBJECT IDENTIFIER
--
-- Protocol Directory Group
--
-- Lists the inventory of protocols the probe has the capability of
-- monitoring and allows the addition, deletion, and configuration of
-- entries in this list.
protocolDirLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time the protocol directory
was last modified, either through insertions or deletions,
or through modifications of either the
protocolDirAddressMapConfig, protocolDirHostConfig, or
protocolDirMatrixConfig."
::= { protocolDir 1 }
Waldbusser Standards Track [Page 15]
RFC 2021 Remote Network Monitoring MIB January 1997
protocolDirTable OBJECT-TYPE
SYNTAX SEQUENCE OF ProtocolDirEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the protocols that this agent has the
capability to decode and count. There is one entry in this
table for each such protocol. These protocols represent
different network layer, transport layer, and higher-layer
protocols. The agent should boot up with this table
preconfigured with those protocols that it knows about and
wishes to monitor. Implementations are strongly encouraged to
support protocols higher than the network layer (at least for
the protocol distribution group), even for implementations
that don't support the application layer groups."
::= { protocolDir 2 }
protocolDirEntry OBJECT-TYPE
SYNTAX ProtocolDirEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the protocolDirTable.
An example of the indexing of this entry is
protocolDirLocalIndex.8.0.0.0.1.0.0.8.0.2.0.0, which is the
encoding of a length of 8, followed by 8 subids encoding the
protocolDirID of 1.2048, followed by a length of 2 and the
2 subids encoding zero-valued parameters."
INDEX { protocolDirID, protocolDirParameters }
::= { protocolDirTable 1 }
ProtocolDirEntry ::= SEQUENCE {
protocolDirID OCTET STRING,
protocolDirParameters OCTET STRING,
protocolDirLocalIndex Integer32,
protocolDirDescr DisplayString,
protocolDirType BITS,
protocolDirAddressMapConfig INTEGER,
protocolDirHostConfig INTEGER,
protocolDirMatrixConfig INTEGER,
protocolDirOwner OwnerString,
protocolDirStatus RowStatus
}
protocolDirID OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS not-accessible
Waldbusser Standards Track [Page 16]
RFC 2021 Remote Network Monitoring MIB January 1997
STATUS current
DESCRIPTION
"A unique identifier for a particular protocol. Standard
identifiers will be defined in a manner such that they
can often be used as specifications for new protocols - i.e.
a tree-structured assignment mechanism that matches the
protocol encapsulation `tree' and which has algorithmic
assignment mechanisms for certain subtrees. See RFC XXX for
more details.
Despite the algorithmic mechanism, the probe will only place
entries in here for those protocols it chooses to collect. In
other words, it need not populate this table with all of the
possible ethernet protocol types, nor need it create them on
the fly when it sees them. Whether or not it does these
things is a matter of product definition (cost/benefit,
usability), and is up to the designer of the product.
If an entry is written to this table with a protocolDirID that
the agent doesn't understand, either directly or
algorithmically, the SET request will be rejected with an
inconsistentName or badValue (for SNMPv1) error."
::= { protocolDirEntry 1 }
protocolDirParameters OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters for the associated protocolDirID.
See the associated RMON2 Protocol Identifiers document
for a description of the possible parameters. There
will be one octet in this string for each sub-identifier in
the protocolDirID, and the parameters will appear here in the
same order as the associated sub-identifiers appear in the
protocolDirID.
Every node in the protocolDirID tree has a different, optional
set of parameters defined (that is, the definition of
parameters for a node is optional). The proper parameter
value for each node is included in this string. Note that the
inclusion of a parameter value in this string for each node is
not optional - what is optional is that a node may have no
parameters defined, in which case the parameter field for that
node will be zero."
::= { protocolDirEntry 2 }
protocolDirLocalIndex OBJECT-TYPE
Waldbusser Standards Track [Page 17]
RFC 2021 Remote Network Monitoring MIB January 1997
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The locally arbitrary, but unique identifier associated
with this protocolDir entry.
The value for each supported protocol must remain constant at
least from one re-initialization of the entity's network
management system to the next re-initialization, except that
if a protocol is deleted and re-created, it must be re-created
with a new value that has not been used since the last
re-initialization.
The specific value is meaningful only within a given SNMP
entity. A protocolDirLocalIndex must not be re-used until the
next agent-restart in the event the protocol directory entry
is deleted."
::= { protocolDirEntry 3 }
protocolDirDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..64))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A textual description of the protocol encapsulation.
A probe may choose to describe only a subset of the
entire encapsulation (e.g. only the highest layer).
This object is intended for human consumption only.
This object may not be modified if the associated
protocolDirStatus object is equal to active(1)."
::= { protocolDirEntry 4 }
protocolDirType OBJECT-TYPE
SYNTAX BITS {
extensible(0),
addressRecognitionCapable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes 2 attributes of this protocol
directory entry.
The presence or absence of the `extensible' bit describes
whether or not this protocol directory entry can be extended
Waldbusser Standards Track [Page 18]
RFC 2021 Remote Network Monitoring MIB January 1997
by the user by creating protocol directory entries which are
children of this protocol.
An example of an entry that will often allow extensibility is
`ip.udp'. The probe may automatically populate some children
of this node such as `ip.udp.snmp' and `ip.udp.dns'.
A probe administrator or user may also populate additional
children via remote SNMP requests that create entries in this
table. When a child node is added for a protocol for which the
probe has no built in support, extending a parent node (for
which the probe does have built in support),
that child node is not extendible. This is termed `limited
extensibility'.
When a child node is added through this extensibility
mechanism, the values of protocolDirLocalIndex and
protocolDirType shall be assigned by the agent.
The other objects in the entry will be assigned by the
manager who is creating the new entry.
This object also describes whether or not this agent can
recognize addresses for this protocol, should it be a network
level protocol. That is, while a probe may be able to
recognize packets of a particular network layer protocol and
count them, it takes additional logic to be able to recognize
the addresses in this protocol and to populate network layer
or application layer tables with the addresses in this
protocol. If this bit is set, the agent will recognize
network layer addresses for this protoocl and populate the
network and application layer host and matrix tables with
these protocols.
Note that when an entry is created, the agent will supply
values for the bits that match the capabilities of the agent
with respect to this protocol. Note that since row creations
usually exercise the limited extensibility feature, these
bits will usually be set to zero."
::= { protocolDirEntry 5 }
protocolDirAddressMapConfig OBJECT-TYPE
SYNTAX INTEGER {
notSupported(1),
supportedOff(2),
supportedOn(3)
}
MAX-ACCESS read-create
STATUS current
Waldbusser Standards Track [Page 19]
RFC 2021 Remote Network Monitoring MIB January 1997
DESCRIPTION
"This object describes and configures the probe's support for
address mapping for this protocol. When the probe creates
entries in this table for all protocols that it understands,
it will set the entry to notSupported(1) if it doesn't have
the capability to perform address mapping for the protocol or
if this protocol is not a network-layer protocol. When
an entry is created in this table by a management operation as
part of the limited extensibility feature, the probe must set
this value to notSupported(1), because limited extensibility
of the protocolDirTable does not extend to interpreting
addresses of the extended protocols.
If the value of this object is notSupported(1), the probe
will not perform address mapping for this protocol and
shall not allow this object to be changed to any other value.
If the value of this object is supportedOn(3), the probe
supports address mapping for this protocol and is configured
to perform address mapping for this protocol for all
addressMappingControlEntries and all interfaces.
If the value of this object is supportedOff(2), the probe
supports address mapping for this protocol but is configured
to not perform address mapping for this protocol for any
addressMappingControlEntries and all interfaces.
Whenever this value changes from supportedOn(3) to
supportedOff(2), the probe shall delete all related entries in
the addressMappingTable."
::= { protocolDirEntry 6 }
protocolDirHostConfig OBJECT-TYPE
SYNTAX INTEGER {
notSupported(1),
supportedOff(2),
supportedOn(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object describes and configures the probe's support for
the network layer and application layer host tables for this
protocol. When the probe creates entries in this table for
all protocols that it understands, it will set the entry to
notSupported(1) if it doesn't have the capability to track the
nlHostTable for this protocol or if the alHostTable is
implemented but doesn't have the capability to track this
protocol. Note that if the alHostTable is implemented, the
probe may only support a protocol if it is supported in both
the nlHostTable and the alHostTable.
Waldbusser Standards Track [Page 20]
RFC 2021 Remote Network Monitoring MIB January 1997
If the associated protocolDirType object has the
addressRecognitionCapable bit set, then this is a network
layer protocol for which the probe recognizes addresses, and
thus the probe will populate the nlHostTable and alHostTable
with addresses it discovers for this protocol.
If the value of this object is notSupported(1), the probe
will not track the nlHostTable or alHostTable for this
protocol and shall not allow this object to be changed to any
other value. If the value of this object is supportedOn(3),
the probe supports tracking of the nlHostTable and alHostTable
for this protocol and is configured to track both tables
for this protocol for all control entries and all interfaces.
If the value of this object is supportedOff(2), the probe
supports tracking of the nlHostTable and alHostTable for this
protocol but is configured to not track these tables
for any control entries or interfaces.
Whenever this value changes from supportedOn(3) to
supportedOff(2), the probe shall delete all related entries in
the nlHostTable and alHostTable.
Note that since each alHostEntry references 2 protocol
directory entries, one for the network address and one for the
type of the highest protocol recognized, that an entry will
only be created in that table if this value is supportedOn(3)
for both protocols."
::= { protocolDirEntry 7 }
protocolDirMatrixConfig OBJECT-TYPE
SYNTAX INTEGER {
notSupported(1),
supportedOff(2),
supportedOn(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object describes and configures the probe's support for
the network layer and application layer matrix tables for this
protocol. When the probe creates entries in this table for
all protocols that it understands, it will set the entry to
notSupported(1) if it doesn't have the capability to track the
nlMatrixTables for this protocol or if the alMatrixTables are
implemented but don't have the capability to track this
protocol. Note that if the alMatrix tables are implemented,
the probe may only support a protocol if it is supported in
the the both of the nlMatrixTables and both of the
alMatrixTables.
Waldbusser Standards Track [Page 21]
RFC 2021 Remote Network Monitoring MIB January 1997
If the associated protocolDirType object has the
addressRecognitionCapable bit set, then this is a network
layer protocol for which the probe recognizes addresses, and
thus the probe will populate both of the nlMatrixTables and
both of the alMatrixTables with addresses it discovers for
this protocol.
If the value of this object is notSupported(1), the probe
will not track either of the nlMatrixTables or the
alMatrixTables for this protocol and shall not allow this
object to be changed to any other value. If the value of this
object is supportedOn(3), the probe supports tracking of both
of the nlMatrixTables and (if implemented) both of the
alMatrixTables for this protocol and is configured to track
these tables for this protocol for all control entries and all
interfaces. If the value of this object is supportedOff(2),
the probe supports tracking of both of the nlMatrixTables and
(if implemented) both of the alMatrixTables for this protocol
but is configured to not track these tables for this
protocol for any control entries or interfaces.
Whenever this value changes from supportedOn(3) to
supportedOff(2), the probe shall delete all related entries in
the nlMatrixTables and the alMatrixTables.
Note that since each alMatrixEntry references 2 protocol
directory entries, one for the network address and one for the
type of the highest protocol recognized, that an entry will
only be created in that table if this value is supportedOn(3)
for both protocols."
::= { protocolDirEntry 8 }
protocolDirOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { protocolDirEntry 9 }
protocolDirStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this protocol directory entry.
An entry may not exist in the active state unless all
Waldbusser Standards Track [Page 22]
RFC 2021 Remote Network Monitoring MIB January 1997
objects in the entry have an appropriate value.
If this object is not equal to active(1), all associated
entries in the nlHostTable, nlMatrixSDTable, nlMatrixDSTable,
alHostTable, alMatrixSDTable, and alMatrixDSTable shall be
deleted."
::= { protocolDirEntry 10 }
--
-- Protocol Distribution Group (protocolDist)
--
-- Collects the relative amounts of octets and packets for the
-- different protocols detected on a network segment.
-- protocolDistControlTable,
-- protocolDistStatsTable
protocolDistControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF ProtocolDistControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Controls the setup of protocol type distribution statistics
tables.
Implementations are encouraged to add an entry per monitored
interface upon initialization so that a default collection
of protocol statistics is available.
Rationale:
This table controls collection of very basic statistics
for any or all of the protocols detected on a given interface.
An NMS can use this table to quickly determine bandwidth
allocation utilized by different protocols.
A media-specific statistics collection could also
be configured (e.g. etherStats, trPStats) to easily obtain
total frame, octet, and droppedEvents for the same
interface."
::= { protocolDist 1 }
protocolDistControlEntry OBJECT-TYPE
SYNTAX ProtocolDistControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the protocolDistControlTable.
An example of the indexing of this entry is
Waldbusser Standards Track [Page 23]
RFC 2021 Remote Network Monitoring MIB January 1997
protocolDistControlDroppedFrames.7"
INDEX { protocolDistControlIndex }
::= { protocolDistControlTable 1 }
ProtocolDistControlEntry ::= SEQUENCE {
protocolDistControlIndex Integer32,
protocolDistControlDataSource DataSource,
protocolDistControlDroppedFrames Counter32,
protocolDistControlCreateTime LastCreateTime,
protocolDistControlOwner OwnerString,
protocolDistControlStatus RowStatus
}
protocolDistControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index for this protocolDistControlEntry."
::= { protocolDistControlEntry 1 }
protocolDistControlDataSource OBJECT-TYPE
SYNTAX DataSource
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The source of data for the this protocol distribution.
The statistics in this group reflect all packets
on the local network segment attached to the
identified interface.
This object may not be modified if the associated
protocolDistControlStatus object is equal to active(1)."
::= { protocolDistControlEntry 2 }
protocolDistControlDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
is out of some resources and decides to shed load from this
collection.
Waldbusser Standards Track [Page 24]
RFC 2021 Remote Network Monitoring MIB January 1997
This count does not include packets that were not counted
because they had MAC-layer errors.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { protocolDistControlEntry 3 }
protocolDistControlCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this control entry was last
activated. This can be used by the management station to
ensure that the table has not been deleted and recreated
between polls."
::= { protocolDistControlEntry 4 }
protocolDistControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { protocolDistControlEntry 5 }
protocolDistControlStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this row.
An entry may not exist in the active state unless all
objects in the entry have an appropriate value.
If this object is not equal to active(1), all associated
entries in the protocolDistStatsTable shall be deleted."
::= { protocolDistControlEntry 6 }
-- per interface protocol distribution statistics table
protocolDistStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF ProtocolDistStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry is made in this table for every protocol in the
Waldbusser Standards Track [Page 25]
RFC 2021 Remote Network Monitoring MIB January 1997
protocolDirTable which has been seen in at least one packet.
Counters are updated in this table for every protocol type
that is encountered when parsing a packet, but no counters are
updated for packets with MAC-layer errors.
Note that if a protocolDirEntry is deleted, all associated
entries in this table are removed."
::= { protocolDist 2 }
protocolDistStatsEntry OBJECT-TYPE
SYNTAX ProtocolDistStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the protocolDistStatsTable.
The index is composed of the protocolDistControlIndex of the
associated protocolDistControlEntry followed by the
protocolDirLocalIndex of the associated protocol that this
entry represents. In other words, the index identifies the
protocol distribution an entry is a part of as well as the
particular protocol that it represents.
An example of the indexing of this entry is
protocolDistStatsPkts.1.18"
INDEX { protocolDistControlIndex, protocolDirLocalIndex }
::= { protocolDistStatsTable 1 }
ProtocolDistStatsEntry ::= SEQUENCE {
protocolDistStatsPkts ZeroBasedCounter32,
protocolDistStatsOctets ZeroBasedCounter32
}
protocolDistStatsPkts OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets without errors received of this
protocol type. Note that this is the number of link-layer
packets, so if a single network-layer packet is fragmented
into several link-layer frames, this counter is incremented
several times."
::= { protocolDistStatsEntry 1 }
protocolDistStatsOctets OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
Waldbusser Standards Track [Page 26]
RFC 2021 Remote Network Monitoring MIB January 1997
STATUS current
DESCRIPTION
"The number of octets in packets received of this protocol
type since it was added to the protocolDistStatsTable
(excluding framing bits but including FCS octets), except for
those octets in packets that contained errors.
Note this doesn't count just those octets in the particular
protocol frames, but includes the entire packet that contained
the protocol."
::= { protocolDistStatsEntry 2 }
--
-- Address Map Group (addressMap)
--
-- Lists MAC address to network address bindings discovered by the
-- probe and what interface they were last seen on.
-- addressMapControlTable
-- addressMapTable
addressMapInserts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times an address mapping entry has been
inserted into the addressMapTable. If an entry is inserted,
then deleted, and then inserted, this counter will be
incremented by 2.
Note that the table size can be determined by subtracting
addressMapDeletes from addressMapInserts."
::= { addressMap 1 }
addressMapDeletes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times an address mapping entry has been
deleted from the addressMapTable (for any reason). If
an entry is deleted, then inserted, and then deleted, this
counter will be incremented by 2.
Note that the table size can be determined by subtracting
addressMapDeletes from addressMapInserts."
::= { addressMap 2 }
Waldbusser Standards Track [Page 27]
RFC 2021 Remote Network Monitoring MIB January 1997
addressMapMaxDesiredEntries OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of entries that are desired in the
addressMapTable. The probe will not create more than
this number of entries in the table, but may choose to create
fewer entries in this table for any reason including the lack
of resources.
If this object is set to a value less than the current number
of entries, enough entries are chosen in an
implementation-dependent manner and deleted so that the number
of entries in the table equals the value of this object.
If this value is set to -1, the probe may create any number
of entries in this table.
This object may be used to control how resources are allocated
on the probe for the various RMON functions."
::= { addressMap 3 }
addressMapControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AddressMapControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table to control the collection of network layer address to
physical address to interface mappings.
Note that this is not like the typical RMON
controlTable and dataTable in which each entry creates
its own data table. Each entry in this table enables the
discovery of addresses on a new interface and the placement
of address mappings into the central addressMapTable.
Implementations are encouraged to add an entry per monitored
interface upon initialization so that a default collection
of address mappings is available."
::= { addressMap 4 }
addressMapControlEntry OBJECT-TYPE
SYNTAX AddressMapControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the addressMapControlTable.
Waldbusser Standards Track [Page 28]
RFC 2021 Remote Network Monitoring MIB January 1997
An example of the indexing of this entry is
addressMapControlDroppedFrames.1"
INDEX { addressMapControlIndex }
::= { addressMapControlTable 1 }
AddressMapControlEntry ::= SEQUENCE {
addressMapControlIndex Integer32,
addressMapControlDataSource DataSource,
addressMapControlDroppedFrames Counter32,
addressMapControlOwner OwnerString,
addressMapControlStatus RowStatus
}
addressMapControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index for this entry in the addressMapControlTable."
::= { addressMapControlEntry 1 }
addressMapControlDataSource OBJECT-TYPE
SYNTAX DataSource
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The source of data for this addressMapControlEntry."
::= { addressMapControlEntry 2 }
addressMapControlDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
is out of some resources and decides to shed load from this
collection.
This count does not include packets that were not counted
because they had MAC-layer errors.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { addressMapControlEntry 3 }
Waldbusser Standards Track [Page 29]
RFC 2021 Remote Network Monitoring MIB January 1997
addressMapControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { addressMapControlEntry 4 }
addressMapControlStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this addressMap control entry.
An entry may not exist in the active state unless all
objects in the entry have an appropriate value.
If this object is not equal to active(1), all associated
entries in the addressMapTable shall be deleted."
::= { addressMapControlEntry 5 }
addressMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF AddressMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of network layer address to physical address to
interface mappings.
The probe will add entries to this table based on the source
MAC and network addresses seen in packets without MAC-level
errors. The probe will populate this table for all protocols
in the protocol directory table whose value of
protocolDirAddressMapConfig is equal to supportedOn(3), and
will delete any entries whose protocolDirEntry is deleted or
has a protocolDirAddressMapConfig value of supportedOff(2)."
::= { addressMap 5 }
addressMapEntry OBJECT-TYPE
SYNTAX AddressMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the addressMapTable.
The protocolDirLocalIndex in the index identifies the network
layer protocol of the addressMapNetworkAddress.
Waldbusser Standards Track [Page 30]
RFC 2021 Remote Network Monitoring MIB January 1997
An example of the indexing of this entry is
addressMapSource.783495.18.4.128.2.6.6.11.1.3.6.1.2.1.2.2.1.1.1"
INDEX { addressMapTimeMark, protocolDirLocalIndex,
addressMapNetworkAddress, addressMapSource }
::= { addressMapTable 1 }
AddressMapEntry ::= SEQUENCE {
addressMapTimeMark TimeFilter,
addressMapNetworkAddress OCTET STRING,
addressMapSource OBJECT IDENTIFIER,
addressMapPhysicalAddress OCTET STRING,
addressMapLastChange TimeStamp
}
addressMapTimeMark OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A TimeFilter for this entry. See the TimeFilter textual
convention to see how this works."
::= { addressMapEntry 1 }
addressMapNetworkAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The network address for this relation.
This is represented as an octet string with
specific semantics and length as identified
by the protocolDirLocalIndex component of the
index.
For example, if the protocolDirLocalIndex indicates an
encapsulation of ip, this object is encoded as a length
octet of 4, followed by the 4 octets of the ip address,
in network byte order."
::= { addressMapEntry 2 }
addressMapSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface or port on which the associated network
address was most recently seen.
Waldbusser Standards Track [Page 31]
RFC 2021 Remote Network Monitoring MIB January 1997
If this address mapping was discovered on an interface, this
object shall identify the instance of the ifIndex
object, defined in [3,5], for the desired interface.
For example, if an entry were to receive data from
interface #1, this object would be set to ifIndex.1.
If this address mapping was discovered on a port, this
object shall identify the instance of the rptrGroupPortIndex
object, defined in [RFC1516], for the desired port.
For example, if an entry were to receive data from
group #1, port #1, this object would be set to
rptrGroupPortIndex.1.1.
Note that while the dataSource associated with this entry
may only point to index objects, this object may at times
point to repeater port objects. This situation occurs when
the dataSource points to an interface which is a locally
attached repeater and the agent has additional information
about the source port of traffic seen on that repeater."
::= { addressMapEntry 3 }
addressMapPhysicalAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last source physical address on which the associated
network address was seen. If the protocol of the associated
network address was encapsulated inside of a network-level or
higher protocol, this will be the address of the next-lower
protocol with the addressRecognitionCapable bit enabled and
will be formatted as specified for that protocol."
::= { addressMapEntry 4 }
addressMapLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time this entry was last
created or the values of the physical address changed.
This can be used to help detect duplicate address problems, in
which case this object will be updated frequently."
::= { addressMapEntry 5 }
--
-- Network Layer Host Group
Waldbusser Standards Track [Page 32]
RFC 2021 Remote Network Monitoring MIB January 1997
--
-- Counts the amount of traffic sent from and to each network address
-- discovered by the probe.
-- Note that while the hlHostControlTable also has objects that
-- control an optional alHostTable, implementation of the alHostTable is
-- not required to fully implement this group.
hlHostControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF HlHostControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of higher layer (i.e. non-MAC) host table control entries.
These entries will enable the collection of the network and
application level host tables indexed by network addresses.
Both the network and application level host tables are
controlled by this table is so that they will both be created
and deleted at the same time, further increasing the ease with
which they can be implemented as a single datastore (note that
if an implementation stores application layer host records in
memory, it can derive network layer host records from them).
Entries in the nlHostTable will be created on behalf of each
entry in this table. Additionally, if this probe implements
the alHostTable, entries in the alHostTable will be created on
behalf of each entry in this table.
Implementations are encouraged to add an entry per monitored
interface upon initialization so that a default collection
of host statistics is available."
::= { nlHost 1 }
hlHostControlEntry OBJECT-TYPE
SYNTAX HlHostControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the hlHostControlTable.
An example of the indexing of this entry is
hlHostControlNlDroppedFrames.1"
INDEX { hlHostControlIndex }
::= { hlHostControlTable 1 }
HlHostControlEntry ::= SEQUENCE {
hlHostControlIndex Integer32,
hlHostControlDataSource DataSource,
Waldbusser Standards Track [Page 33]
RFC 2021 Remote Network Monitoring MIB January 1997
hlHostControlNlDroppedFrames Counter32,
hlHostControlNlInserts Counter32,
hlHostControlNlDeletes Counter32,
hlHostControlNlMaxDesiredEntries Integer32,
hlHostControlAlDroppedFrames Counter32,
hlHostControlAlInserts Counter32,
hlHostControlAlDeletes Counter32,
hlHostControlAlMaxDesiredEntries Integer32,
hlHostControlOwner OwnerString,
hlHostControlStatus RowStatus
}
hlHostControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
hlHostControlTable. Each such entry defines
a function that discovers hosts on a particular
interface and places statistics about them in the
nlHostTable, and optionally in the alHostTable, on
behalf of this hlHostControlEntry."
::= { hlHostControlEntry 1 }
hlHostControlDataSource OBJECT-TYPE
SYNTAX DataSource
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The source of data for the associated host tables.
The statistics in this group reflect all packets
on the local network segment attached to the
identified interface.
This object may not be modified if the associated
hlHostControlStatus object is equal to active(1)."
::= { hlHostControlEntry 2 }
hlHostControlNlDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for the associated
Waldbusser Standards Track [Page 34]
RFC 2021 Remote Network Monitoring MIB January 1997
nlHost entries for whatever reason. Most often, this event
occurs when the probe is out of some resources and decides to
shed load from this collection.
This count does not include packets that were not counted
because they had MAC-layer errors.
Note that if the nlHostTable is inactive because no protocols
are enabled in the protocol directory, this value should be 0.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { hlHostControlEntry 3 }
hlHostControlNlInserts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times an nlHost entry has been
inserted into the nlHost table. If an entry is inserted, then
deleted, and then inserted, this counter will be incremented
by 2.
To allow for efficient implementation strategies, agents may
delay updating this object for short periods of time. For
example, an implementation strategy may allow internal
data structures to differ from those visible via SNMP for
short periods of time. This counter may reflect the internal
data structures for those short periods of time.
Note that the table size can be determined by subtracting
hlHostControlNlDeletes from hlHostControlNlInserts."
::= { hlHostControlEntry 4 }
hlHostControlNlDeletes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times an nlHost entry has been
deleted from the nlHost table (for any reason). If an entry
is deleted, then inserted, and then deleted, this counter will
be incremented by 2.
To allow for efficient implementation strategies, agents may
delay updating this object for short periods of time. For
example, an implementation strategy may allow internal
Waldbusser Standards Track [Page 35]
RFC 2021 Remote Network Monitoring MIB January 1997
data structures to differ from those visible via SNMP for
short periods of time. This counter may reflect the internal
data structures for those short periods of time.
Note that the table size can be determined by subtracting
hlHostControlNlDeletes from hlHostControlNlInserts."
::= { hlHostControlEntry 5 }
hlHostControlNlMaxDesiredEntries OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of entries that are desired in the
nlHostTable on behalf of this control entry. The probe will
not create more than this number of associated entries in the
table, but may choose to create fewer entries in this table
for any reason including the lack of resources.
If this object is set to a value less than the current number
of entries, enough entries are chosen in an
implementation-dependent manner and deleted so that the number
of entries in the table equals the value of this object.
If this value is set to -1, the probe may create any number
of entries in this table. If the associated
hlHostControlStatus object is equal to `active', this
object may not be modified.
This object may be used to control how resources are allocated
on the probe for the various RMON functions."
::= { hlHostControlEntry 6 }
hlHostControlAlDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for the associated
alHost entries for whatever reason. Most often, this event
occurs when the probe is out of some resources and decides to
shed load from this collection.
This count does not include packets that were not counted
because they had MAC-layer errors.
Waldbusser Standards Track [Page 36]
RFC 2021 Remote Network Monitoring MIB January 1997
Note that if the alHostTable is not implemented or is inactive
because no protocols are enabled in the protocol directory,
this value should be 0.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { hlHostControlEntry 7 }
hlHostControlAlInserts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times an alHost entry has been
inserted into the alHost table. If an entry is inserted, then
deleted, and then inserted, this counter will be incremented
by 2.
To allow for efficient implementation strategies, agents may
delay updating this object for short periods of time. For
example, an implementation strategy may allow internal
data structures to differ from those visible via SNMP for
short periods of time. This counter may reflect the internal
data structures for those short periods of time.
Note that the table size can be determined by subtracting
hlHostControlAlDeletes from hlHostControlAlInserts."
::= { hlHostControlEntry 8 }
hlHostControlAlDeletes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times an alHost entry has been
deleted from the alHost table (for any reason). If an entry
is deleted, then inserted, and then deleted, this counter will
be incremented by 2.
To allow for efficient implementation strategies, agents may
delay updating this object for short periods of time. For
example, an implementation strategy may allow internal
data structures to differ from those visible via SNMP for
short periods of time. This counter may reflect the internal
data structures for those short periods of time.
Note that the table size can be determined by subtracting
hlHostControlAlDeletes from hlHostControlAlInserts."
Waldbusser Standards Track [Page 37]
RFC 2021 Remote Network Monitoring MIB January 1997
::= { hlHostControlEntry 9 }
hlHostControlAlMaxDesiredEntries OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of entries that are desired in the alHost
table on behalf of this control entry. The probe will not
create more than this number of associated entries in the
table, but may choose to create fewer entries in this table
for any reason including the lack of resources.
If this object is set to a value less than the current number
of entries, enough entries are chosen in an
implementation-dependent manner and deleted so that the number
of entries in the table equals the value of this object.
If this value is set to -1, the probe may create any number
of entries in this table. If the associated
hlHostControlStatus object is equal to `active', this
object may not be modified.
This object may be used to control how resources are allocated
on the probe for the various RMON functions."
::= { hlHostControlEntry 10 }
hlHostControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { hlHostControlEntry 11 }
hlHostControlStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this hlHostControlEntry.
An entry may not exist in the active state unless all
objects in the entry have an appropriate value.
If this object is not equal to active(1), all associated
entries in the nlHostTable and alHostTable shall be deleted."
Waldbusser Standards Track [Page 38]
RFC 2021 Remote Network Monitoring MIB January 1997
::= { hlHostControlEntry 12 }
nlHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF NlHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of statistics for a particular network layer
address that has been discovered on an interface of this
device.
The probe will populate this table for all network layer
protocols in the protocol directory table whose value of
protocolDirHostConfig is equal to supportedOn(3), and
will delete any entries whose protocolDirEntry is deleted or
has a protocolDirHostConfig value of supportedOff(2).
The probe will add to this table all addresses seen
as the source or destination address in all packets with no
MAC errors, and will increment octet and packet counts in the
table for all packets with no MAC errors."
::= { nlHost 2 }
nlHostEntry OBJECT-TYPE
SYNTAX NlHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the nlHostTable.
The hlHostControlIndex value in the index identifies the
hlHostControlEntry on whose behalf this entry was created.
The protocolDirLocalIndex value in the index identifies the
network layer protocol of the nlHostAddress.
An example of the indexing of this entry is
nlHostOutPkts.1.783495.18.4.128.2.6.6."
INDEX { hlHostControlIndex, nlHostTimeMark,
protocolDirLocalIndex, nlHostAddress }
::= { nlHostTable 1 }
NlHostEntry ::= SEQUENCE {
nlHostTimeMark TimeFilter,
nlHostAddress OCTET STRING,
nlHostInPkts ZeroBasedCounter32,
nlHostOutPkts ZeroBasedCounter32,
nlHostInOctets ZeroBasedCounter32,
nlHostOutOctets ZeroBasedCounter32,
Waldbusser Standards Track [Page 39]
RFC 2021 Remote Network Monitoring MIB January 1997
nlHostOutMacNonUnicastPkts ZeroBasedCounter32,
nlHostCreateTime LastCreateTime
}
nlHostTimeMark OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A TimeFilter for this entry. See the TimeFilter textual
convention to see how this works."
::= { nlHostEntry 1 }
nlHostAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The network address for this nlHostEntry.
This is represented as an octet string with
specific semantics and length as identified
by the protocolDirLocalIndex component of the index.
For example, if the protocolDirLocalIndex indicates an
encapsulation of ip, this object is encoded as a length
octet of 4, followed by the 4 octets of the ip address,
in network byte order."
::= { nlHostEntry 2 }
nlHostInPkts OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets without errors transmitted to
this address since it was added to the nlHostTable. Note that
this is the number of link-layer packets, so if a single
network-layer packet is fragmented into several link-layer
frames, this counter is incremented several times."
::= { nlHostEntry 3 }
nlHostOutPkts OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets without errors transmitted by
Waldbusser Standards Track [Page 40]
RFC 2021 Remote Network Monitoring MIB January 1997
this address since it was added to the nlHostTable. Note that
this is the number of link-layer packets, so if a single
network-layer packet is fragmented into several link-layer
frames, this counter is incremented several times."
::= { nlHostEntry 4 }
nlHostInOctets OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets transmitted to this address
since it was added to the nlHostTable (excluding
framing bits but including FCS octets), excluding
those octets in packets that contained errors.
Note this doesn't count just those octets in the particular
protocol frames, but includes the entire packet that contained
the protocol."
::= { nlHostEntry 5 }
nlHostOutOctets OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets transmitted by this address
since it was added to the nlHostTable (excluding
framing bits but including FCS octets), excluding
those octets in packets that contained errors.
Note this doesn't count just those octets in the particular
protocol frames, but includes the entire packet that contained
the protocol."
::= { nlHostEntry 6 }
nlHostOutMacNonUnicastPkts OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets without errors transmitted by this
address that were directed to any MAC broadcast addresses
or to any MAC multicast addresses since this host was
added to the nlHostTable. Note that this is the number of
link-layer packets, so if a single network-layer packet is
fragmented into several link-layer frames, this counter is
incremented several times."
Waldbusser Standards Track [Page 41]
RFC 2021 Remote Network Monitoring MIB January 1997
::= { nlHostEntry 7 }
nlHostCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this entry was last activated.
This can be used by the management station to ensure that the
entry has not been deleted and recreated between polls."
::= { nlHostEntry 8 }
--
-- Network Layer Matrix Group
--
-- Counts the amount of traffic sent between each pair of network
-- addresses discovered by the probe.
-- Note that while the hlMatrixControlTable also has objects that
-- control optional alMatrixTables, implementation of the
-- alMatrixTables is not required to fully implement this group.
hlMatrixControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF HlMatrixControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of higher layer (i.e. non-MAC) matrix control entries.
These entries will enable the collection of the network and
application level matrix tables containing conversation
statistics indexed by pairs of network addresses.
Both the network and application level matrix tables are
controlled by this table is so that they will both be created
and deleted at the same time, further increasing the ease with
which they can be implemented as a single datastore (note that
if an implementation stores application layer matrix records
in memory, it can derive network layer matrix records from
them).
Entries in the nlMatrixSDTable and nlMatrixDSTable will be
created on behalf of each entry in this table. Additionally,
if this probe implements the alMatrix tables, entries in the
alMatrix tables will be created on behalf of each entry in
this table."
::= { nlMatrix 1 }
hlMatrixControlEntry OBJECT-TYPE
SYNTAX HlMatrixControlEntry
Waldbusser Standards Track [Page 42]
RFC 2021 Remote Network Monitoring MIB January 1997
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the hlMatrixControlTable.
An example of indexing of this entry is
hlMatrixControlNlDroppedFrames.1"
INDEX { hlMatrixControlIndex }
::= { hlMatrixControlTable 1 }
HlMatrixControlEntry ::= SEQUENCE {
hlMatrixControlIndex Integer32,
hlMatrixControlDataSource DataSource,
hlMatrixControlNlDroppedFrames Counter32,
hlMatrixControlNlInserts Counter32,
hlMatrixControlNlDeletes Counter32,
hlMatrixControlNlMaxDesiredEntries Integer32,
hlMatrixControlAlDroppedFrames Counter32,
hlMatrixControlAlInserts Counter32,
hlMatrixControlAlDeletes Counter32,
hlMatrixControlAlMaxDesiredEntries Integer32,
hlMatrixControlOwner OwnerString,
hlMatrixControlStatus RowStatus
}
hlMatrixControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
hlMatrixControlTable. Each such entry defines
a function that discovers conversations on a particular
interface and places statistics about them in the
nlMatrixSDTable and the nlMatrixDSTable, and optionally the
alMatrixSDTable and alMatrixDSTable, on behalf of this
hlMatrixControlEntry."
::= { hlMatrixControlEntry 1 }
hlMatrixControlDataSource OBJECT-TYPE
SYNTAX DataSource
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The source of the data for the associated matrix tables.
The statistics in this group reflect all packets
on the local network segment attached to the
Waldbusser Standards Track [Page 43]
RFC 2021 Remote Network Monitoring MIB January 1997
identified interface.
This object may not be modified if the associated
hlMatrixControlStatus object is equal to active(1)."
::= { hlMatrixControlEntry 2 }
hlMatrixControlNlDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
is out of some resources and decides to shed load from this
collection.
This count does not include packets that were not counted
because they had MAC-layer errors.
Note that if the nlMatrixTables are inactive because no
protocols are enabled in the protocol directory, this value
should be 0.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { hlMatrixControlEntry 3 }
hlMatrixControlNlInserts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times an nlMatrix entry has been
inserted into the nlMatrix tables. If an entry is inserted,
then deleted, and then inserted, this counter will be
incremented by 2. The addition of a conversation into both
the nlMatrixSDTable and nlMatrixDSTable shall be counted as
two insertions (even though every addition into one table must
be accompanied by an insertion into the other).
To allow for efficient implementation strategies, agents may
delay updating this object for short periods of time. For
example, an implementation strategy may allow internal
data structures to differ from those visible via SNMP for
short periods of time. This counter may reflect the internal
data structures for those short periods of time.
Waldbusser Standards Track [Page 44]
RFC 2021 Remote Network Monitoring MIB January 1997
Note that the sum of then nlMatrixSDTable and nlMatrixDSTable
sizes can be determined by subtracting
hlMatrixControlNlDeletes from hlMatrixControlNlInserts."
::= { hlMatrixControlEntry 4 }
hlMatrixControlNlDeletes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times an nlMatrix entry has been
deleted from the nlMatrix tables (for any reason). If an
entry is deleted, then inserted, and then deleted, this
counter will be incremented by 2. The deletion of a
conversation from both the nlMatrixSDTable and nlMatrixDSTable
shall be counted as two deletions (even though every deletion
from one table must be accompanied by a deletion from the
other).
To allow for efficient implementation strategies, agents may
delay updating this object for short periods of time. For
example, an implementation strategy may allow internal
data structures to differ from those visible via SNMP for
short periods of time. This counter may reflect the internal
data structures for those short periods of time.
Note that the table size can be determined by subtracting
hlMatrixControlNlDeletes from hlMatrixControlNlInserts."
::= { hlMatrixControlEntry 5 }
hlMatrixControlNlMaxDesiredEntries OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of entries that are desired in the
nlMatrix tables on behalf of this control entry. The probe
will not create more than this number of associated entries in
the table, but may choose to create fewer entries in this
table for any reason including the lack of resources.
If this object is set to a value less than the current number
of entries, enough entries are chosen in an
implementation-dependent manner and deleted so that the number
of entries in the table equals the value of this object.
If this value is set to -1, the probe may create any number
of entries in this table. If the associated
Waldbusser Standards Track [Page 45]
RFC 2021 Remote Network Monitoring MIB January 1997
hlMatrixControlStatus object is equal to `active', this
object may not be modified.
This object may be used to control how resources are allocated
on the probe for the various RMON functions."
::= { hlMatrixControlEntry 6 }
hlMatrixControlAlDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
is out of some resources and decides to shed load from this
collection.
This count does not include packets that were not counted
because they had MAC-layer errors.
Note that if the alMatrixTables are not implemented or are
inactive because no protocols are enabled in the protocol
directory, this value should be 0.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { hlMatrixControlEntry 7 }
hlMatrixControlAlInserts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times an alMatrix entry has been
inserted into the alMatrix tables. If an entry is inserted,
then deleted, and then inserted, this counter will be
incremented by 2. The addition of a conversation into both
the alMatrixSDTable and alMatrixDSTable shall be counted as
two insertions (even though every addition into one table must
be accompanied by an insertion into the other).
To allow for efficient implementation strategies, agents may
delay updating this object for short periods of time. For
example, an implementation strategy may allow internal
data structures to differ from those visible via SNMP for
short periods of time. This counter may reflect the internal
Waldbusser Standards Track [Page 46]
RFC 2021 Remote Network Monitoring MIB January 1997
data structures for those short periods of time.
Note that the table size can be determined by subtracting
hlMatrixControlAlDeletes from hlMatrixControlAlInserts."
::= { hlMatrixControlEntry 8 }
hlMatrixControlAlDeletes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times an alMatrix entry has been
deleted from the alMatrix tables. If an entry is deleted,
then inserted, and then deleted, this counter will be
incremented by 2. The deletion of a conversation from both
the alMatrixSDTable and alMatrixDSTable shall be counted as
two deletions (even though every deletion from one table must
be accompanied by a deletion from the other).
To allow for efficient implementation strategies, agents may
delay updating this object for short periods of time. For
example, an implementation strategy may allow internal
data structures to differ from those visible via SNMP for
short periods of time. This counter may reflect the internal
data structures for those short periods of time.
Note that the table size can be determined by subtracting
hlMatrixControlAlDeletes from hlMatrixControlAlInserts."
::= { hlMatrixControlEntry 9 }
hlMatrixControlAlMaxDesiredEntries OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of entries that are desired in the
alMatrix tables on behalf of this control entry. The probe
will not create more than this number of associated entries in
the table, but may choose to create fewer entries in this
table for any reason including the lack of resources.
If this object is set to a value less than the current number
of entries, enough entries are chosen in an
implementation-dependent manner and deleted so that the number
of entries in the table equals the value of this object.
If this value is set to -1, the probe may create any number
of entries in this table. If the associated
Waldbusser Standards Track [Page 47]
RFC 2021 Remote Network Monitoring MIB January 1997
hlMatrixControlStatus object is equal to `active', this
object may not be modified.
This object may be used to control how resources are allocated
on the probe for the various RMON functions."
::= { hlMatrixControlEntry 10 }
hlMatrixControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { hlMatrixControlEntry 11 }
hlMatrixControlStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this hlMatrixControlEntry.
An entry may not exist in the active state unless all
objects in the entry have an appropriate value.
If this object is not equal to active(1), all
associated entries in the nlMatrixSDTable,
nlMatrixDSTable, alMatrixSDTable, and the alMatrixDSTable
shall be deleted by the agent."
::= { hlMatrixControlEntry 12 }
nlMatrixSDTable OBJECT-TYPE
SYNTAX SEQUENCE OF NlMatrixSDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of traffic matrix entries which collect statistics for
conversations between two network-level addresses. This table
is indexed first by the source address and then by the
destination address to make it convenient to collect all
conversations from a particular address.
The probe will populate this table for all network layer
protocols in the protocol directory table whose value of
protocolDirMatrixConfig is equal to supportedOn(3), and
will delete any entries whose protocolDirEntry is deleted or
has a protocolDirMatrixConfig value of supportedOff(2).
Waldbusser Standards Track [Page 48]
RFC 2021 Remote Network Monitoring MIB January 1997
The probe will add to this table all pairs of addresses
seen in all packets with no MAC errors, and will increment
octet and packet counts in the table for all packets with no
MAC errors.
Further, this table will only contain entries that have a
corresponding entry in the nlMatrixDSTable with the same
source address and destination address."
::= { nlMatrix 2 }
nlMatrixSDEntry OBJECT-TYPE
SYNTAX NlMatrixSDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the nlMatrixSDTable.
The hlMatrixControlIndex value in the index identifies the
hlMatrixControlEntry on whose behalf this entry was created.
The protocolDirLocalIndex value in the index identifies the
network layer protocol of the nlMatrixSDSourceAddress and
nlMatrixSDDestAddress.
An example of the indexing of this table is
nlMatrixSDPkts.1.783495.18.4.128.2.6.6.4.128.2.6.7"
INDEX { hlMatrixControlIndex, nlMatrixSDTimeMark,
protocolDirLocalIndex,
nlMatrixSDSourceAddress, nlMatrixSDDestAddress }
::= { nlMatrixSDTable 1 }
NlMatrixSDEntry ::= SEQUENCE {
nlMatrixSDTimeMark TimeFilter,
nlMatrixSDSourceAddress OCTET STRING,
nlMatrixSDDestAddress OCTET STRING,
nlMatrixSDPkts ZeroBasedCounter32,
nlMatrixSDOctets ZeroBasedCounter32,
nlMatrixSDCreateTime LastCreateTime
}
nlMatrixSDTimeMark OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A TimeFilter for this entry. See the TimeFilter textual
convention to see how this works."
::= { nlMatrixSDEntry 1 }
Waldbusser Standards Track [Page 49]
RFC 2021 Remote Network Monitoring MIB January 1997
nlMatrixSDSourceAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The network source address for this nlMatrixSDEntry.
This is represented as an octet string with
specific semantics and length as identified
by the protocolDirLocalIndex component of the index.
For example, if the protocolDirLocalIndex indicates an
encapsulation of ip, this object is encoded as a length
octet of 4, followed by the 4 octets of the ip address,
in network byte order."
::= { nlMatrixSDEntry 2 }
nlMatrixSDDestAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The network destination address for this
nlMatrixSDEntry.
This is represented as an octet string with
specific semantics and length as identified
by the protocolDirLocalIndex component of the index.
For example, if the protocolDirLocalIndex indicates an
encapsulation of ip, this object is encoded as a length
octet of 4, followed by the 4 octets of the ip address,
in network byte order."
::= { nlMatrixSDEntry 3 }
nlMatrixSDPkts OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets without errors transmitted from the
source address to the destination address since this entry was
added to the nlMatrixSDTable. Note that this is the number of
link-layer packets, so if a single network-layer packet is
fragmented into several link-layer frames, this counter is
incremented several times."
::= { nlMatrixSDEntry 4 }
Waldbusser Standards Track [Page 50]
RFC 2021 Remote Network Monitoring MIB January 1997
nlMatrixSDOctets OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets transmitted from the source address to
the destination address since this entry was added to the
nlMatrixSDTable (excluding framing bits but
including FCS octets), excluding those octets in packets that
contained errors.
Note this doesn't count just those octets in the particular
protocol frames, but includes the entire packet that contained
the protocol."
::= { nlMatrixSDEntry 5 }
nlMatrixSDCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this entry was last activated.
This can be used by the management station to ensure that the
entry has not been deleted and recreated between polls."
::= { nlMatrixSDEntry 6 }
-- Traffic matrix tables from destination to source
nlMatrixDSTable OBJECT-TYPE
SYNTAX SEQUENCE OF NlMatrixDSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of traffic matrix entries which collect statistics for
conversations between two network-level addresses. This table
is indexed first by the destination address and then by the
source address to make it convenient to collect all
conversations to a particular address.
The probe will populate this table for all network layer
protocols in the protocol directory table whose value of
protocolDirMatrixConfig is equal to supportedOn(3), and
will delete any entries whose protocolDirEntry is deleted or
has a protocolDirMatrixConfig value of supportedOff(2).
The probe will add to this table all pairs of addresses
seen in all packets with no MAC errors, and will increment
Waldbusser Standards Track [Page 51]
RFC 2021 Remote Network Monitoring MIB January 1997
octet and packet counts in the table for all packets with no
MAC errors.
Further, this table will only contain entries that have a
corresponding entry in the nlMatrixSDTable with the same
source address and destination address."
::= { nlMatrix 3 }
nlMatrixDSEntry OBJECT-TYPE
SYNTAX NlMatrixDSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the nlMatrixDSTable.
The hlMatrixControlIndex value in the index identifies the
hlMatrixControlEntry on whose behalf this entry was created.
The protocolDirLocalIndex value in the index identifies the
network layer protocol of the nlMatrixDSSourceAddress and
nlMatrixDSDestAddress.
An example of the indexing of this table is
nlMatrixDSPkts.1.783495.18.4.128.2.6.7.4.128.2.6.6"
INDEX { hlMatrixControlIndex, nlMatrixDSTimeMark,
protocolDirLocalIndex,
nlMatrixDSDestAddress, nlMatrixDSSourceAddress }
::= { nlMatrixDSTable 1 }
NlMatrixDSEntry ::= SEQUENCE {
nlMatrixDSTimeMark TimeFilter,
nlMatrixDSSourceAddress OCTET STRING,
nlMatrixDSDestAddress OCTET STRING,
nlMatrixDSPkts ZeroBasedCounter32,
nlMatrixDSOctets ZeroBasedCounter32,
nlMatrixDSCreateTime LastCreateTime
}
nlMatrixDSTimeMark OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A TimeFilter for this entry. See the TimeFilter textual
convention to see how this works."
::= { nlMatrixDSEntry 1 }
nlMatrixDSSourceAddress OBJECT-TYPE
SYNTAX OCTET STRING
Waldbusser Standards Track [Page 52]
RFC 2021 Remote Network Monitoring MIB January 1997
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The network source address for this nlMatrixDSEntry.
This is represented as an octet string with
specific semantics and length as identified
by the protocolDirLocalIndex component of the index.
For example, if the protocolDirLocalIndex indicates an
encapsulation of ip, this object is encoded as a length
octet of 4, followed by the 4 octets of the ip address,
in network byte order."
::= { nlMatrixDSEntry 2 }
nlMatrixDSDestAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The network destination address for this
nlMatrixDSEntry.
This is represented as an octet string with
specific semantics and length as identified
by the protocolDirLocalIndex component of the index.
For example, if the protocolDirLocalIndex indicates an
encapsulation of ip, this object is encoded as a length
octet of 4, followed by the 4 octets of the ip address,
in network byte order."
::= { nlMatrixDSEntry 3 }
nlMatrixDSPkts OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets without errors transmitted from the
source address to the destination address since this entry was
added to the nlMatrixDSTable. Note that this is the number of
link-layer packets, so if a single network-layer packet is
fragmented into several link-layer frames, this counter is
incremented several times."
::= { nlMatrixDSEntry 4 }
nlMatrixDSOctets OBJECT-TYPE
SYNTAX ZeroBasedCounter32
Waldbusser Standards Track [Page 53]
RFC 2021 Remote Network Monitoring MIB January 1997
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets transmitted from the source address
to the destination address since this entry was added to the
nlMatrixDSTable (excluding framing bits but
including FCS octets), excluding those octets in packets that
contained errors.
Note this doesn't count just those octets in the particular
protocol frames, but includes the entire packet that contained
the protocol."
::= { nlMatrixDSEntry 5 }
nlMatrixDSCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this entry was last activated.
This can be used by the management station to ensure that the
entry has not been deleted and recreated between polls."
::= { nlMatrixDSEntry 6 }
nlMatrixTopNControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF NlMatrixTopNControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters that control the creation of a
report of the top N matrix entries according to
a selected metric."
::= { nlMatrix 4 }
nlMatrixTopNControlEntry OBJECT-TYPE
SYNTAX NlMatrixTopNControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the nlMatrixTopNControlTable.
An example of the indexing of this table is
nlMatrixTopNControlDuration.3"
INDEX { nlMatrixTopNControlIndex }
::= { nlMatrixTopNControlTable 1 }
NlMatrixTopNControlEntry ::= SEQUENCE {
nlMatrixTopNControlIndex Integer32,
Waldbusser Standards Track [Page 54]
RFC 2021 Remote Network Monitoring MIB January 1997
nlMatrixTopNControlMatrixIndex Integer32,
nlMatrixTopNControlRateBase INTEGER,
nlMatrixTopNControlTimeRemaining Integer32,
nlMatrixTopNControlGeneratedReports Counter32,
nlMatrixTopNControlDuration Integer32,
nlMatrixTopNControlRequestedSize Integer32,
nlMatrixTopNControlGrantedSize Integer32,
nlMatrixTopNControlStartTime TimeStamp,
nlMatrixTopNControlOwner OwnerString,
nlMatrixTopNControlStatus RowStatus
}
nlMatrixTopNControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry
in the nlMatrixTopNControlTable. Each such
entry defines one top N report prepared for
one interface."
::= { nlMatrixTopNControlEntry 1 }
nlMatrixTopNControlMatrixIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The nlMatrix[SD/DS] table for which a top N report will be
prepared on behalf of this entry. The nlMatrix[SD/DS] table
is identified by the value of the hlMatrixControlIndex
for that table - that value is used here to identify the
particular table.
This object may not be modified if the associated
nlMatrixTopNControlStatus object is equal to active(1)."
::= { nlMatrixTopNControlEntry 2 }
nlMatrixTopNControlRateBase OBJECT-TYPE
SYNTAX INTEGER {
nlMatrixTopNPkts(1),
nlMatrixTopNOctets(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The variable for each nlMatrix[SD/DS] entry that the
nlMatrixTopNEntries are sorted by.
Waldbusser Standards Track [Page 55]
RFC 2021 Remote Network Monitoring MIB January 1997
This object may not be modified if the associated
nlMatrixTopNControlStatus object is equal to active(1)."
::= { nlMatrixTopNControlEntry 3 }
nlMatrixTopNControlTimeRemaining OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of seconds left in the report currently
being collected. When this object is modified by
the management station, a new collection is started,
possibly aborting a currently running report. The
new value is used as the requested duration of this
report, and is immediately loaded into the associated
nlMatrixTopNControlDuration object.
When the report finishes, the probe will automatically
start another collection with the same initial value
of nlMatrixTopNControlTimeRemaining. Thus the management
station may simply read the resulting reports repeatedly,
checking the startTime and duration each time to ensure that a
report was not missed or that the report parameters were not
changed.
While the value of this object is non-zero, it decrements
by one per second until it reaches zero. At the time
that this object decrements to zero, the report is made
accessible in the nlMatrixTopNTable, overwriting any report
that may be there.
When this object is modified by the management station, any
associated entries in the nlMatrixTopNTable shall be deleted.
(Note that this is a different algorithm than the one used in
the hostTopNTable)."
DEFVAL { 1800 }
::= { nlMatrixTopNControlEntry 4 }
nlMatrixTopNControlGeneratedReports OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of reports that have been generated by this entry."
::= { nlMatrixTopNControlEntry 5 }
nlMatrixTopNControlDuration OBJECT-TYPE
SYNTAX Integer32
Waldbusser Standards Track [Page 56]
RFC 2021 Remote Network Monitoring MIB January 1997
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that this report has collected
during the last sampling interval.
When the associated nlMatrixTopNControlTimeRemaining object is
set, this object shall be set by the probe to the
same value and shall not be modified until the next
time the nlMatrixTopNControlTimeRemaining is set.
This value shall be zero if no reports have been
requested for this nlMatrixTopNControlEntry."
::= { nlMatrixTopNControlEntry 6 }
nlMatrixTopNControlRequestedSize OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of matrix entries requested for this report.
When this object is created or modified, the probe
should set nlMatrixTopNControlGrantedSize as closely to this
object as is possible for the particular probe
implementation and available resources."
DEFVAL { 150 }
::= { nlMatrixTopNControlEntry 7 }
nlMatrixTopNControlGrantedSize OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of matrix entries in this report.
When the associated nlMatrixTopNControlRequestedSize object is
created or modified, the probe should set this
object as closely to the requested value as is
possible for the particular implementation and
available resources. The probe must not lower this
value except as a result of a set to the associated
nlMatrixTopNControlRequestedSize object.
If the value of nlMatrixTopNControlRateBase is equal to
nlMatrixTopNPkts, when the next topN report is generated,
matrix entries with the highest value of nlMatrixTopNPktRate
shall be placed in this table in decreasing order of this rate
until there is no more room or until there are no more
Waldbusser Standards Track [Page 57]
RFC 2021 Remote Network Monitoring MIB January 1997
matrix entries.
If the value of nlMatrixTopNControlRateBase is equal to
nlMatrixTopNOctets, when the next topN report is generated,
matrix entries with the highest value of nlMatrixTopNOctetRate
shall be placed in this table in decreasing order of this rate
until there is no more room or until there are no more
matrix entries.
It is an implementation-specific matter how entries with the
same value of nlMatrixTopNPktRate or nlMatrixTopNOctetRate are
sorted. It is also an implementation-specific matter as to
whether or not zero-valued entries are available."
::= { nlMatrixTopNControlEntry 8 }
nlMatrixTopNControlStartTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this top N report was
last started. In other words, this is the time that
the associated nlMatrixTopNControlTimeRemaining object was
modified to start the requested report or the time
the report was last automatically (re)started.
This object may be used by the management station to
determine if a report was missed or not."
::= { nlMatrixTopNControlEntry 9 }
nlMatrixTopNControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { nlMatrixTopNControlEntry 10 }
nlMatrixTopNControlStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this nlMatrixTopNControlEntry.
An entry may not exist in the active state unless all
objects in the entry have an appropriate value.
Waldbusser Standards Track [Page 58]
RFC 2021 Remote Network Monitoring MIB January 1997
If this object is not equal to active(1), all
associated entries in the nlMatrixTopNTable shall be deleted
by the agent."
::= { nlMatrixTopNControlEntry 11 }
nlMatrixTopNTable OBJECT-TYPE
SYNTAX SEQUENCE OF NlMatrixTopNEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of statistics for those network layer matrix entries
that have counted the highest number of octets or packets."
::= { nlMatrix 5 }
nlMatrixTopNEntry OBJECT-TYPE
SYNTAX NlMatrixTopNEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the nlMatrixTopNTable.
The nlMatrixTopNControlIndex value in the index identifies the
nlMatrixTopNControlEntry on whose behalf this entry was
created.
An example of the indexing of this table is
nlMatrixTopNPktRate.3.10"
INDEX { nlMatrixTopNControlIndex, nlMatrixTopNIndex }
::= { nlMatrixTopNTable 1 }
NlMatrixTopNEntry ::= SEQUENCE {
nlMatrixTopNIndex Integer32,
nlMatrixTopNProtocolDirLocalIndex Integer32,
nlMatrixTopNSourceAddress OCTET STRING,
nlMatrixTopNDestAddress OCTET STRING,
nlMatrixTopNPktRate Gauge32,
nlMatrixTopNReversePktRate Gauge32,
nlMatrixTopNOctetRate Gauge32,
nlMatrixTopNReverseOctetRate Gauge32
}
nlMatrixTopNIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in
the nlMatrixTopNTable among those in the same report.
Waldbusser Standards Track [Page 59]
RFC 2021 Remote Network Monitoring MIB January 1997
This index is between 1 and N, where N is the
number of entries in this report.
If the value of nlMatrixTopNControlRateBase is equal to
nlMatrixTopNPkts, increasing values of nlMatrixTopNIndex shall
be assigned to entries with decreasing values of
nlMatrixTopNPktRate until index N is assigned or there are no
more nlMatrixTopNEntries.
If the value of nlMatrixTopNControlRateBase is equal to
nlMatrixTopNOctets, increasing values of nlMatrixTopNIndex
shall be assigned to entries with decreasing values of
nlMatrixTopNOctetRate until index N is assigned or there are
no more nlMatrixTopNEntries."
::= { nlMatrixTopNEntry 1 }
nlMatrixTopNProtocolDirLocalIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protocolDirLocalIndex of the network layer protocol of
this entry's network address."
::= { nlMatrixTopNEntry 2 }
nlMatrixTopNSourceAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The network layer address of the source host in this
conversation.
This is represented as an octet string with
specific semantics and length as identified
by the associated nlMatrixTopNProtocolDirLocalIndex.
For example, if the protocolDirLocalIndex indicates an
encapsulation of ip, this object is encoded as a length
octet of 4, followed by the 4 octets of the ip address,
in network byte order."
::= { nlMatrixTopNEntry 3 }
nlMatrixTopNDestAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Waldbusser Standards Track [Page 60]
RFC 2021 Remote Network Monitoring MIB January 1997
"The network layer address of the destination host in this
conversation.
This is represented as an octet string with
specific semantics and length as identified
by the associated nlMatrixTopNProtocolDirLocalIndex.
For example, if the nlMatrixTopNProtocolDirLocalIndex
indicates an encapsulation of ip, this object is encoded as a
length octet of 4, followed by the 4 octets of the ip address,
in network byte order."
::= { nlMatrixTopNEntry 4 }
nlMatrixTopNPktRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets seen from the source host
to the destination host during this sampling interval, counted
using the rules for counting the nlMatrixSDPkts object.
If the value of nlMatrixTopNControlRateBase is
nlMatrixTopNPkts, this variable will be used to sort this
report."
::= { nlMatrixTopNEntry 5 }
nlMatrixTopNReversePktRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets seen from the destination host to the
source host during this sampling interval, counted
using the rules for counting the nlMatrixSDPkts object (note
that the corresponding nlMatrixSDPkts object selected is the
one whose source address is equal to nlMatrixTopNDestAddress
and whose destination address is equal to
nlMatrixTopNSourceAddress.)
Note that if the value of nlMatrixTopNControlRateBase is equal
to nlMatrixTopNPkts, the sort of topN entries is based
entirely on nlMatrixTopNPktRate, and not on the value of this
object."
::= { nlMatrixTopNEntry 6 }
nlMatrixTopNOctetRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
Waldbusser Standards Track [Page 61]
RFC 2021 Remote Network Monitoring MIB January 1997
STATUS current
DESCRIPTION
"The number of octets seen from the source host
to the destination host during this sampling interval, counted
using the rules for counting the nlMatrixSDOctets object. If
the value of nlMatrixTopNControlRateBase is
nlMatrixTopNOctets, this variable will be used to sort this
report."
::= { nlMatrixTopNEntry 7 }
nlMatrixTopNReverseOctetRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets seen from the destination host to the
source host during this sampling interval, counted
using the rules for counting the nlMatrixDSOctets object (note
that the corresponding nlMatrixSDOctets object selected is the
one whose source address is equal to nlMatrixTopNDestAddress
and whose destination address is equal to
nlMatrixTopNSourceAddress.)
Note that if the value of nlMatrixTopNControlRateBase is equal
to nlMatrixTopNOctets, the sort of topN entries is based
entirely on nlMatrixTopNOctetRate, and not on the value of
this object."
::= { nlMatrixTopNEntry 8 }
-- Application Layer Functions
--
-- The application layer host, matrix, and matrixTopN functions report
-- on protocol usage at the network layer or higher. Note that the
-- use of the term application layer does not imply that only
-- application-layer protocols are counted, rather it means that
-- protocols up to and including the application layer are supported.
--
-- Application Layer Host Group
--
-- Counts the amount of traffic, by protocol, sent from and to each
-- network address discovered by the probe.
-- Implementation of this group requires implementation of the Network
-- Layer Host Group.
alHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlHostEntry
MAX-ACCESS not-accessible
Waldbusser Standards Track [Page 62]
RFC 2021 Remote Network Monitoring MIB January 1997
STATUS current
DESCRIPTION
"A collection of statistics for a particular protocol from a
particular network address that has been discovered on an
interface of this device.
The probe will populate this table for all protocols in the
protocol directory table whose value of
protocolDirHostConfig is equal to supportedOn(3), and
will delete any entries whose protocolDirEntry is deleted or
has a protocolDirHostConfig value of supportedOff(2).
The probe will add to this table all addresses
seen as the source or destination address in all packets with
no MAC errors, and will increment octet and packet counts in
the table for all packets with no MAC errors. Further,
entries will only be added to this table if their address
exists in the nlHostTable and will be deleted from this table
if their address is deleted from the nlHostTable."
::= { alHost 1 }
alHostEntry OBJECT-TYPE
SYNTAX AlHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the alHostTable.
The hlHostControlIndex value in the index identifies the
hlHostControlEntry on whose behalf this entry was created.
The first protocolDirLocalIndex value in the index identifies
the network layer protocol of the address.
The nlHostAddress value in the index identifies the network
layer address of this entry.
The second protocolDirLocalIndex value in the index identifies
the protocol that is counted by this entry.
An example of the indexing in this entry is
alHostOutPkts.1.783495.18.4.128.2.6.6.34"
INDEX { hlHostControlIndex, alHostTimeMark,
protocolDirLocalIndex, nlHostAddress,
protocolDirLocalIndex }
::= { alHostTable 1 }
AlHostEntry ::= SEQUENCE {
alHostTimeMark TimeFilter,
alHostInPkts ZeroBasedCounter32,
alHostOutPkts ZeroBasedCounter32,
Waldbusser Standards Track [Page 63]
RFC 2021 Remote Network Monitoring MIB January 1997
alHostInOctets ZeroBasedCounter32,
alHostOutOctets ZeroBasedCounter32,
alHostCreateTime LastCreateTime
}
alHostTimeMark OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A TimeFilter for this entry. See the TimeFilter textual
convention to see how this works."
::= { alHostEntry 1 }
alHostInPkts OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets of this protocol type without errors
transmitted to this address since it was added to the
alHostTable. Note that this is the number of link-layer
packets, so if a single network-layer packet is fragmented
into several link-layer frames, this counter is incremented
several times."
::= { alHostEntry 2 }
alHostOutPkts OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets of this protocol type without errors
transmitted by this address since it was added to the
alHostTable. Note that this is the number of link-layer
packets, so if a single network-layer packet is fragmented
into several link-layer frames, this counter is incremented
several times."
::= { alHostEntry 3 }
alHostInOctets OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets transmitted to this address
of this protocol type since it was added to the
alHostTable (excluding framing bits but including
Waldbusser Standards Track [Page 64]
RFC 2021 Remote Network Monitoring MIB January 1997
FCS octets), excluding those octets in packets that
contained errors.
Note this doesn't count just those octets in the particular
protocol frames, but includes the entire packet that contained
the protocol."
::= { alHostEntry 4 }
alHostOutOctets OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets transmitted by this address
of this protocol type since it was added to the
alHostTable (excluding framing bits but including
FCS octets), excluding those octets in packets that
contained errors.
Note this doesn't count just those octets in the particular
protocol frames, but includes the entire packet that contained
the protocol."
::= { alHostEntry 5 }
alHostCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this entry was last activated.
This can be used by the management station to ensure that the
entry has not been deleted and recreated between polls."
::= { alHostEntry 6 }
--
-- Application Layer Matrix Group
--
-- Counts the amount of traffic, by protocol, sent between each pair
-- of network addresses discovered by the probe.
-- Implementation of this group requires implementation of the Network
-- Layer Matrix Group.
alMatrixSDTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlMatrixSDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of application traffic matrix entries which collect
Waldbusser Standards Track [Page 65]
RFC 2021 Remote Network Monitoring MIB January 1997
statistics for conversations of a particular protocol between
two network-level addresses. This table is indexed first by
the source address and then by the destination address to make
it convenient to collect all statistics from a particular
address.
The probe will populate this table for all protocols in the
protocol directory table whose value of
protocolDirMatrixConfig is equal to supportedOn(3), and
will delete any entries whose protocolDirEntry is deleted or
has a protocolDirMatrixConfig value of supportedOff(2).
The probe will add to this table all pairs of addresses for
all protocols seen in all packets with no MAC errors, and will
increment octet and packet counts in the table for all packets
with no MAC errors. Further, entries will only be added to
this table if their address pair exists in the nlMatrixSDTable
and will be deleted from this table if the address pair is
deleted from the nlMatrixSDTable."
::= { alMatrix 1 }
alMatrixSDEntry OBJECT-TYPE
SYNTAX AlMatrixSDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the alMatrixSDTable.
The hlMatrixControlIndex value in the index identifies the
hlMatrixControlEntry on whose behalf this entry was created.
The first protocolDirLocalIndex value in the index identifies
the network layer protocol of the nlMatrixSDSourceAddress and
nlMatrixSDDestAddress.
The nlMatrixSDSourceAddress value in the index identifies the
network layer address of the source host in this conversation.
The nlMatrixSDDestAddress value in the index identifies the
network layer address of the destination host in this
conversation.
The second protocolDirLocalIndex value in the index identifies
the protocol that is counted by this entry.
An example of the indexing of this entry is
alMatrixSDPkts.1.783495.18.4.128.2.6.6.4.128.2.6.7.34"
INDEX { hlMatrixControlIndex, alMatrixSDTimeMark,
protocolDirLocalIndex,
nlMatrixSDSourceAddress, nlMatrixSDDestAddress,
protocolDirLocalIndex }
::= { alMatrixSDTable 1 }
Waldbusser Standards Track [Page 66]
RFC 2021 Remote Network Monitoring MIB January 1997
AlMatrixSDEntry ::= SEQUENCE {
alMatrixSDTimeMark TimeFilter,
alMatrixSDPkts ZeroBasedCounter32,
alMatrixSDOctets ZeroBasedCounter32,
alMatrixSDCreateTime LastCreateTime
}
alMatrixSDTimeMark OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A TimeFilter for this entry. See the TimeFilter textual
convention to see how this works."
::= { alMatrixSDEntry 1 }
alMatrixSDPkts OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets of this protocol type without errors
transmitted from the source address to the destination address
since this entry was added to the alMatrixSDTable. Note that
this is the number of link-layer packets, so if a single
network-layer packet is fragmented into several link-layer
frames, this counter is incremented several times."
::= { alMatrixSDEntry 2 }
alMatrixSDOctets OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets in packets of this protocol type
transmitted from the source address to the destination address
since this entry was added to the alMatrixSDTable (excluding
framing bits but including FCS octets), excluding those octets
in packets that contained errors.
Note this doesn't count just those octets in the particular
protocol frames, but includes the entire packet that contained
the protocol."
::= { alMatrixSDEntry 3 }
alMatrixSDCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
Waldbusser Standards Track [Page 67]
RFC 2021 Remote Network Monitoring MIB January 1997
STATUS current
DESCRIPTION
"The value of sysUpTime when this entry was last activated.
This can be used by the management station to ensure that the
entry has not been deleted and recreated between polls."
::= { alMatrixSDEntry 4 }
-- Traffic matrix tables from destination to source
alMatrixDSTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlMatrixDSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of application traffic matrix entries which collect
statistics for conversations of a particular protocol between
two network-level addresses. This table is indexed first by
the destination address and then by the source address to make
it convenient to collect all statistics to a particular
address.
The probe will populate this table for all protocols in the
protocol directory table whose value of
protocolDirMatrixConfig is equal to supportedOn(3), and
will delete any entries whose protocolDirEntry is deleted or
has a protocolDirMatrixConfig value of supportedOff(2).
The probe will add to this table all pairs of addresses for
all protocols seen in all packets with no MAC errors, and will
increment octet and packet counts in the table for all packets
with no MAC errors. Further, entries will only be added to
this table if their address pair exists in the nlMatrixDSTable
and will be deleted from this table if the address pair is
deleted from the nlMatrixDSTable."
::= { alMatrix 2 }
alMatrixDSEntry OBJECT-TYPE
SYNTAX AlMatrixDSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the alMatrixDSTable.
The hlMatrixControlIndex value in the index identifies the
hlMatrixControlEntry on whose behalf this entry was created.
The first protocolDirLocalIndex value in the index identifies
the network layer protocol of the alMatrixDSSourceAddress and
alMatrixDSDestAddress.
Waldbusser Standards Track [Page 68]
RFC 2021 Remote Network Monitoring MIB January 1997
The nlMatrixDSDestAddress value in the index identifies the
network layer address of the destination host in this
conversation.
The nlMatrixDSSourceAddress value in the index identifies the
network layer address of the source host in this conversation.
The second protocolDirLocalIndex value in the index identifies
the protocol that is counted by this entry.
An example of the indexing of this entry is
alMatrixDSPkts.1.783495.18.4.128.2.6.7.4.128.2.6.6.34"
INDEX { hlMatrixControlIndex, alMatrixDSTimeMark,
protocolDirLocalIndex,
nlMatrixDSDestAddress, nlMatrixDSSourceAddress,
protocolDirLocalIndex }
::= { alMatrixDSTable 1 }
AlMatrixDSEntry ::= SEQUENCE {
alMatrixDSTimeMark TimeFilter,
alMatrixDSPkts ZeroBasedCounter32,
alMatrixDSOctets ZeroBasedCounter32,
alMatrixDSCreateTime LastCreateTime
}
alMatrixDSTimeMark OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A TimeFilter for this entry. See the TimeFilter textual
convention to see how this works."
::= { alMatrixDSEntry 1 }
alMatrixDSPkts OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets of this protocol type without errors
transmitted from the source address to the destination address
since this entry was added to the alMatrixDSTable. Note that
this is the number of link-layer packets, so if a single
network-layer packet is fragmented into several link-layer
frames, this counter is incremented several times."
::= { alMatrixDSEntry 2 }
alMatrixDSOctets OBJECT-TYPE
SYNTAX ZeroBasedCounter32
MAX-ACCESS read-only
Waldbusser Standards Track [Page 69]
RFC 2021 Remote Network Monitoring MIB January 1997
STATUS current
DESCRIPTION
"The number of octets in packets of this protocol type
transmitted from the source address to the destination address
since this entry was added to the alMatrixDSTable (excluding
framing bits but including FCS octets), excluding those octets
in packets that contained errors.
Note this doesn't count just those octets in the particular
protocol frames, but includes the entire packet that contained
the protocol."
::= { alMatrixDSEntry 3 }
alMatrixDSCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this entry was last activated.
This can be used by the management station to ensure that the
entry has not been deleted and recreated between polls."
::= { alMatrixDSEntry 4 }
alMatrixTopNControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlMatrixTopNControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters that control the creation of a
report of the top N matrix entries according to
a selected metric."
::= { alMatrix 3 }
alMatrixTopNControlEntry OBJECT-TYPE
SYNTAX AlMatrixTopNControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the alMatrixTopNControlTable.
An example of the indexing of this table is
alMatrixTopNControlDuration.3"
INDEX { alMatrixTopNControlIndex }
::= { alMatrixTopNControlTable 1 }
AlMatrixTopNControlEntry ::= SEQUENCE {
alMatrixTopNControlIndex Integer32,
alMatrixTopNControlMatrixIndex Integer32,
Waldbusser Standards Track [Page 70]
RFC 2021 Remote Network Monitoring MIB January 1997
alMatrixTopNControlRateBase INTEGER,
alMatrixTopNControlTimeRemaining Integer32,
alMatrixTopNControlGeneratedReports Counter32,
alMatrixTopNControlDuration Integer32,
alMatrixTopNControlRequestedSize Integer32,
alMatrixTopNControlGrantedSize Integer32,
alMatrixTopNControlStartTime TimeStamp,
alMatrixTopNControlOwner OwnerString,
alMatrixTopNControlStatus RowStatus
}
alMatrixTopNControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry
in the alMatrixTopNControlTable. Each such
entry defines one top N report prepared for
one interface."
::= { alMatrixTopNControlEntry 1 }
alMatrixTopNControlMatrixIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The alMatrix[SD/DS] table for which a top N report will be
prepared on behalf of this entry. The alMatrix[SD/DS] table
is identified by the value of the hlMatrixControlIndex
for that table - that value is used here to identify the
particular table.
This object may not be modified if the associated
alMatrixTopNControlStatus object is equal to active(1)."
::= { alMatrixTopNControlEntry 2 }
alMatrixTopNControlRateBase OBJECT-TYPE
SYNTAX INTEGER {
alMatrixTopNTerminalsPkts(1),
alMatrixTopNTerminalsOctets(2),
alMatrixTopNAllPkts(3),
alMatrixTopNAllOctets(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The variable for each alMatrix[SD/DS] entry that the
Waldbusser Standards Track [Page 71]
RFC 2021 Remote Network Monitoring MIB January 1997
alMatrixTopNEntries are sorted by, as well as the
selector of the view of the matrix table that will be
used.
The values alMatrixTopNTerminalsPkts and
alMatrixTopNTerminalsOctets cause collection only from
protocols that have no child protocols that are counted. The
values alMatrixTopNAllPkts and alMatrixTopNAllOctets cause
collection from all alMatrix entries.
This object may not be modified if the associated
alMatrixTopNControlStatus object is equal to active(1)."
::= { alMatrixTopNControlEntry 3 }
alMatrixTopNControlTimeRemaining OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of seconds left in the report currently
being collected. When this object is modified by
the management station, a new collection is started,
possibly aborting a currently running report. The
new value is used as the requested duration of this
report, and is immediately loaded into the associated
alMatrixTopNControlDuration object.
When the report finishes, the probe will automatically
start another collection with the same initial value
of alMatrixTopNControlTimeRemaining. Thus the management
station may simply read the resulting reports repeatedly,
checking the startTime and duration each time to ensure that a
report was not missed or that the report parameters were not
changed.
While the value of this object is non-zero, it decrements
by one per second until it reaches zero. At the time
that this object decrements to zero, the report is made
accessible in the alMatrixTopNTable, overwriting any report
that may be there.
When this object is modified by the management station, any
associated entries in the alMatrixTopNTable shall be deleted.
(Note that this is a different algorithm than the one used in
the hostTopNTable)."
DEFVAL { 1800 }
::= { alMatrixTopNControlEntry 4 }
Waldbusser Standards Track [Page 72]
RFC 2021 Remote Network Monitoring MIB January 1997
alMatrixTopNControlGeneratedReports OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of reports that have been generated by this entry."
::= { alMatrixTopNControlEntry 5 }
alMatrixTopNControlDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that this report has collected
during the last sampling interval.
When the associated alMatrixTopNControlTimeRemaining object
is set, this object shall be set by the probe to the
same value and shall not be modified until the next
time the alMatrixTopNControlTimeRemaining is set.
This value shall be zero if no reports have been
requested for this alMatrixTopNControlEntry."
::= { alMatrixTopNControlEntry 6 }
alMatrixTopNControlRequestedSize OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of matrix entries requested for this report.
When this object is created or modified, the probe
should set alMatrixTopNControlGrantedSize as closely to this
object as is possible for the particular probe
implementation and available resources."
DEFVAL { 150 }
::= { alMatrixTopNControlEntry 7 }
alMatrixTopNControlGrantedSize OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of matrix entries in this report.
When the associated alMatrixTopNControlRequestedSize object
is created or modified, the probe should set this
Waldbusser Standards Track [Page 73]
RFC 2021 Remote Network Monitoring MIB January 1997
object as closely to the requested value as is
possible for the particular implementation and
available resources. The probe must not lower this
value except as a result of a set to the associated
alMatrixTopNControlRequestedSize object.
If the value of alMatrixTopNControlRateBase is equal to
alMatrixTopNTerminalsPkts or alMatrixTopNAllPkts, when the
next topN report is generated, matrix entries with the highest
value of alMatrixTopNPktRate shall be placed in this table in
decreasing order of this rate until there is no more room or
until there are no more matrix entries.
If the value of alMatrixTopNControlRateBase is equal to
alMatrixTopNTerminalsOctets or alMatrixTopNAllOctets, when the
next topN report is generated, matrix entries with the highest
value of alMatrixTopNOctetRate shall be placed in this table
in decreasing order of this rate until there is no more room
or until there are no more matrix entries.
It is an implementation-specific matter how entries with the
same value of alMatrixTopNPktRate or alMatrixTopNOctetRate are
sorted. It is also an implementation-specific matter as to
whether or not zero-valued entries are available."
::= { alMatrixTopNControlEntry 8 }
alMatrixTopNControlStartTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this top N report was
last started. In other words, this is the time that
the associated alMatrixTopNControlTimeRemaining object
was modified to start the requested report or the time
the report was last automatically (re)started.
This object may be used by the management station to
determine if a report was missed or not."
::= { alMatrixTopNControlEntry 9 }
alMatrixTopNControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
Waldbusser Standards Track [Page 74]
RFC 2021 Remote Network Monitoring MIB January 1997
::= { alMatrixTopNControlEntry 10 }
alMatrixTopNControlStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this alMatrixTopNControlEntry.
An entry may not exist in the active state unless all
objects in the entry have an appropriate value.
If this object is not equal to active(1), all
associated entries in the alMatrixTopNTable shall be
deleted by the agent."
::= { alMatrixTopNControlEntry 11 }
alMatrixTopNTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlMatrixTopNEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of statistics for those application layer matrix
entries that have counted the highest number of octets or
packets."
::= { alMatrix 4 }
alMatrixTopNEntry OBJECT-TYPE
SYNTAX AlMatrixTopNEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the alMatrixTopNTable.
The alMatrixTopNControlIndex value in the index identifies
the alMatrixTopNControlEntry on whose behalf this entry was
created.
An example of the indexing of this table is
alMatrixTopNPktRate.3.10"
INDEX { alMatrixTopNControlIndex, alMatrixTopNIndex }
::= { alMatrixTopNTable 1 }
AlMatrixTopNEntry ::= SEQUENCE {
alMatrixTopNIndex Integer32,
alMatrixTopNProtocolDirLocalIndex Integer32,
alMatrixTopNSourceAddress OCTET STRING,
alMatrixTopNDestAddress OCTET STRING,
Waldbusser Standards Track [Page 75]
RFC 2021 Remote Network Monitoring MIB January 1997
alMatrixTopNAppProtocolDirLocalIndex Integer32,
alMatrixTopNPktRate Gauge32,
alMatrixTopNReversePktRate Gauge32,
alMatrixTopNOctetRate Gauge32,
alMatrixTopNReverseOctetRate Gauge32
}
alMatrixTopNIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in
the alMatrixTopNTable among those in the same report.
This index is between 1 and N, where N is the
number of entries in this report.
If the value of alMatrixTopNControlRateBase is equal to
alMatrixTopNTerminalsPkts or alMatrixTopNAllPkts, increasing
values of alMatrixTopNIndex shall be assigned to entries with
decreasing values of alMatrixTopNPktRate until index N is
assigned or there are no more alMatrixTopNEntries.
If the value of alMatrixTopNControlRateBase is equal to
alMatrixTopNTerminalsOctets or alMatrixTopNAllOctets,
increasing values of alMatrixTopNIndex shall be assigned to
entries with decreasing values of alMatrixTopNOctetRate until
index N is assigned or there are no more alMatrixTopNEntries."
::= { alMatrixTopNEntry 1 }
alMatrixTopNProtocolDirLocalIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protocolDirLocalIndex of the network layer protocol of
this entry's network address."
::= { alMatrixTopNEntry 2 }
alMatrixTopNSourceAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The network layer address of the source host in this
conversation.
This is represented as an octet string with
specific semantics and length as identified
Waldbusser Standards Track [Page 76]
RFC 2021 Remote Network Monitoring MIB January 1997
by the associated alMatrixTopNProtocolDirLocalIndex.
For example, if the alMatrixTopNProtocolDirLocalIndex
indicates an encapsulation of ip, this object is encoded as a
length octet of 4, followed by the 4 octets of the ip address,
in network byte order."
::= { alMatrixTopNEntry 3 }
alMatrixTopNDestAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The network layer address of the destination host in this
conversation.
This is represented as an octet string with
specific semantics and length as identified
by the associated alMatrixTopNProtocolDirLocalIndex.
For example, if the alMatrixTopNProtocolDirLocalIndex
indicates an encapsulation of ip, this object is encoded as a
length octet of 4, followed by the 4 octets of the ip address,
in network byte order."
::= { alMatrixTopNEntry 4 }
alMatrixTopNAppProtocolDirLocalIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the protocol counted by this matrix entry."
::= { alMatrixTopNEntry 5 }
alMatrixTopNPktRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets seen of this protocol from the source
host to the destination host during this sampling interval,
counted using the rules for counting the alMatrixSDPkts
object.
If the value of alMatrixTopNControlRateBase is
alMatrixTopNTerminalsPkts or alMatrixTopNAllPkts, this
variable will be used to sort this report."
::= { alMatrixTopNEntry 6 }
Waldbusser Standards Track [Page 77]
RFC 2021 Remote Network Monitoring MIB January 1997
alMatrixTopNReversePktRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets seen of this protocol from the
destination host to the source host during this sampling
interval, counted using the rules for counting the
alMatrixDSPkts object (note that the corresponding
alMatrixSDPkts object selected is the one whose source address
is equal to alMatrixTopNDestAddress and whose destination
address is equal to alMatrixTopNSourceAddress.)
Note that if the value of alMatrixTopNControlRateBase is equal
to alMatrixTopNTerminalsPkts or alMatrixTopNAllPkts, the sort
of topN entries is based entirely on alMatrixTopNPktRate, and
not on the value of this object."
::= { alMatrixTopNEntry 7 }
alMatrixTopNOctetRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets seen of this protocol from the source
host to the destination host during this sampling interval,
counted using the rules for counting the alMatrixSDOctets
object.
If the value of alMatrixTopNControlRateBase is
alMatrixTopNTerminalsOctets or alMatrixTopNAllOctets, this
variable will be used to sort this report."
::= { alMatrixTopNEntry 8 }
alMatrixTopNReverseOctetRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets seen of this protocol from the
destination host to the source host during this sampling
interval, counted using the rules for counting the
alMatrixDSOctets object (note that the corresponding
alMatrixSDOctets object selected is the one whose source
address is equal to alMatrixTopNDestAddress and whose
destination address is equal to alMatrixTopNSourceAddress.)
Note that if the value of alMatrixTopNControlRateBase is equal
Waldbusser Standards Track [Page 78]
RFC 2021 Remote Network Monitoring MIB January 1997
to alMatrixTopNTerminalsOctets or alMatrixTopNAllOctets, the
sort of topN entries is based entirely on
alMatrixTopNOctetRate, and not on the value of this object."
::= { alMatrixTopNEntry 9 }
--
-- User History Collection Group (usrHistory)
--
-- The usrHistory group combines mechanisms seen in the alarm and
-- history groups to provide user-specified history collection,
-- utilizing two additional control tables and one additional data
-- table. This function has traditionally been done by NMS
-- applications, via periodic polling. The usrHistory group allows
-- this task to be offloaded to an RMON probe.
--
-- Data (an ASN.1 INTEGER based object) is collected in the same
-- manner as any history data table (e.g. etherHistoryTable) except
-- that the user specifies the MIB instances to be collected. Objects
-- are collected in bucket-groups, with the intent that all MIB
-- instances in the same bucket-group are collected as atomically as
-- possible by the RMON probe.
--
-- The usrHistoryControlTable is a one-dimensional read-create table.
-- Each row configures a collection of user history buckets, much
-- the same as a historyControlEntry, except that the creation of a
-- row in this table will cause one or more associated instances in
-- the usrHistoryObjectTable to be created. The user specifies the
-- number of bucket elements (rows in the usrHistoryObjectTable)
-- requested, as well as the number of buckets requested.
--
-- The usrHistoryObjectTable is a 2-d read-write table.
-- Each row configures a single MIB instance to be collected.
-- All rows with the same major index constitute a bucket-group.
--
-- The usrHistoryTable is a 3-d read-only table containing
-- the data of associated usrHistoryControlEntries. Each
-- entry represents the value of a single MIB instance
-- during a specific sampling interval (or the rate of
-- change during the interval).
--
-- A sample value is stored in two objects - an absolute value and
-- a status object. This allows numbers from -(2G-1) to +4G to be
-- stored. The status object also indicates whether a sample is
-- valid. This allows data collection to continue if periodic
-- retrieval of a particular instance fails for any reason.
--
-- Row Creation Order Relationships
--
Waldbusser Standards Track [Page 79]
RFC 2021 Remote Network Monitoring MIB January 1997
-- The static nature of the usrHistoryObjectTable creates
-- some row creation/modification issues. The rows in this
-- table need to be set before the associated
-- usrHistoryControlEntry can be activated.
--
-- Note that the usrHistoryObject entries associated with a
-- particular usrHistoryControlEntry are not required to
-- be active before the control entry is activated. However,
-- the usrHistory data entries associated with an inactive
-- usrHistoryObject entry will be inactive (i.e.
-- usrHistoryValStatus == valueNotAvailable).
--
usrHistoryControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF UsrHistoryControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of data-collection configuration entries."
::= { usrHistory 1 }
usrHistoryControlEntry OBJECT-TYPE
SYNTAX UsrHistoryControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of parameters that set up a group of user-defined
MIB objects to be sampled periodically (called a
bucket-group).
For example, an instance of usrHistoryControlInterval
might be named usrHistoryControlInterval.1"
INDEX { usrHistoryControlIndex }
::= { usrHistoryControlTable 1 }
UsrHistoryControlEntry ::= SEQUENCE {
usrHistoryControlIndex Integer32,
usrHistoryControlObjects Integer32,
usrHistoryControlBucketsRequested Integer32,
usrHistoryControlBucketsGranted Integer32,
usrHistoryControlInterval Integer32,
usrHistoryControlOwner OwnerString,
usrHistoryControlStatus RowStatus
}
usrHistoryControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
Waldbusser Standards Track [Page 80]
RFC 2021 Remote Network Monitoring MIB January 1997
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
usrHistoryControlTable. Each such entry defines a
set of samples at a particular interval for a specified
set of MIB instances available from the managed system."
::= { usrHistoryControlEntry 1 }
usrHistoryControlObjects OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of MIB objects to be collected
in the portion of usrHistoryTable associated with this
usrHistoryControlEntry.
This object may not be modified if the associated instance
of usrHistoryControlStatus is equal to active(1)."
::= { usrHistoryControlEntry 2 }
usrHistoryControlBucketsRequested OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The requested number of discrete time intervals
over which data is to be saved in the part of the
usrHistoryTable associated with this usrHistoryControlEntry.
When this object is created or modified, the probe
should set usrHistoryControlBucketsGranted as closely to
this object as is possible for the particular probe
implementation and available resources."
DEFVAL { 50 }
::= { usrHistoryControlEntry 3 }
usrHistoryControlBucketsGranted OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of discrete sampling intervals
over which data shall be saved in the part of
the usrHistoryTable associated with this
usrHistoryControlEntry.
When the associated usrHistoryControlBucketsRequested
Waldbusser Standards Track [Page 81]
RFC 2021 Remote Network Monitoring MIB January 1997
object is created or modified, the probe should set
this object as closely to the requested value as is
possible for the particular probe implementation and
available resources. The probe must not lower this
value except as a result of a modification to the associated
usrHistoryControlBucketsRequested object.
The associated usrHistoryControlBucketsRequested object
should be set before or at the same time as this object
to allow the probe to accurately estimate the resources
required for this usrHistoryControlEntry.
There will be times when the actual number of buckets
associated with this entry is less than the value of
this object. In this case, at the end of each sampling
interval, a new bucket will be added to the usrHistoryTable.
When the number of buckets reaches the value of this object
and a new bucket is to be added to the usrHistoryTable,
the oldest bucket associated with this usrHistoryControlEntry
shall be deleted by the agent so that the new bucket can be
added.
When the value of this object changes to a value less than
the current value, entries are deleted from the
usrHistoryTable associated with this usrHistoryControlEntry.
Enough of the oldest of these entries shall be deleted by the
agent so that their number remains less than or equal to the
new value of this object.
When the value of this object changes to a value greater
than the current value, the number of associated usrHistory
entries may be allowed to grow."
::= { usrHistoryControlEntry 4 }
usrHistoryControlInterval OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The interval in seconds over which the data is
sampled for each bucket in the part of the usrHistory
table associated with this usrHistoryControlEntry.
Because the counters in a bucket may overflow at their
maximum value with no indication, a prudent manager will
take into account the possibility of overflow in any of
Waldbusser Standards Track [Page 82]
RFC 2021 Remote Network Monitoring MIB January 1997
the associated counters. It is important to consider the
minimum time in which any counter could overflow on a
particular media type and set the usrHistoryControlInterval
object to a value less than this interval.
This object may not be modified if the associated
usrHistoryControlStatus object is equal to active(1)."
DEFVAL { 1800 }
::= { usrHistoryControlEntry 5 }
usrHistoryControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { usrHistoryControlEntry 6 }
usrHistoryControlStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this variable history control entry.
An entry may not exist in the active state unless all
objects in the entry have an appropriate value.
If this object is not equal to active(1), all associated
entries in the usrHistoryTable shall be deleted."
::= { usrHistoryControlEntry 7 }
-- Object table
usrHistoryObjectTable OBJECT-TYPE
SYNTAX SEQUENCE OF UsrHistoryObjectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of data-collection configuration entries."
::= { usrHistory 2 }
usrHistoryObjectEntry OBJECT-TYPE
SYNTAX UsrHistoryObjectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
Waldbusser Standards Track [Page 83]
RFC 2021 Remote Network Monitoring MIB January 1997
"A list of MIB instances to be sampled periodically.
Entries in this table are created when an associated
usrHistoryControlObjects object is created.
The usrHistoryControlIndex value in the index is
that of the associated usrHistoryControlEntry.
For example, an instance of usrHistoryObjectVariable might be
usrHistoryObjectVariable.1.3"
INDEX { usrHistoryControlIndex, usrHistoryObjectIndex }
::= { usrHistoryObjectTable 1 }
UsrHistoryObjectEntry ::= SEQUENCE {
usrHistoryObjectIndex Integer32,
usrHistoryObjectVariable OBJECT IDENTIFIER,
usrHistoryObjectSampleType INTEGER
}
usrHistoryObjectIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index used to uniquely identify an entry in the
usrHistoryObject table. Each such entry defines a
MIB instance to be collected periodically."
::= { usrHistoryObjectEntry 1 }
usrHistoryObjectVariable OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object identifier of the particular variable to be
sampled.
Only variables that resolve to an ASN.1 primitive type of
Integer32 (Integer32, Counter, Gauge, or TimeTicks) may be
sampled.
Because SNMP access control is articulated entirely in terms
of the contents of MIB views, no access control mechanism
exists that can restrict the value of this object to identify
only those objects that exist in a particular MIB view.
Because there is thus no acceptable means of restricting the
read access that could be obtained through the user history
Waldbusser Standards Track [Page 84]
RFC 2021 Remote Network Monitoring MIB January 1997
mechanism, the probe must only grant write access to this
object in those views that have read access to all objects on
the probe.
During a set operation, if the supplied variable name is not
available in the selected MIB view, a badValue error must be
returned.
This object may not be modified if the associated
usrHistoryControlStatus object is equal to active(1)."
::= { usrHistoryObjectEntry 2 }
usrHistoryObjectSampleType OBJECT-TYPE
SYNTAX INTEGER {
absoluteValue(1),
deltaValue(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The method of sampling the selected variable for storage in
the usrHistoryTable.
If the value of this object is absoluteValue(1), the value of
the selected variable will be copied directly into the history
bucket.
If the value of this object is deltaValue(2), the value of the
selected variable at the last sample will be subtracted from
the current value, and the difference will be stored in the
history bucket. If the associated usrHistoryObjectVariable
instance could not be obtained at the previous sample
interval, then a delta sample is not possible, and the value
of the associated usrHistoryValStatus object for this interval
will be valueNotAvailable(1).
This object may not be modified if the associated
usrHistoryControlStatus object is equal to active(1)."
::= { usrHistoryObjectEntry 3 }
-- data table
usrHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF UsrHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of user defined history entries."
Waldbusser Standards Track [Page 85]
RFC 2021 Remote Network Monitoring MIB January 1997
::= { usrHistory 3 }
usrHistoryEntry OBJECT-TYPE
SYNTAX UsrHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A historical sample of user-defined variables. This sample
is associated with the usrHistoryControlEntry which set up the
parameters for a regular collection of these samples.
The usrHistoryControlIndex value in the index identifies the
usrHistoryControlEntry on whose behalf this entry was created.
The usrHistoryObjectIndex value in the index identifies the
usrHistoryObjectEntry on whose behalf this entry was created.
For example, an instance of usrHistoryAbsValue, which represents
the 14th sample of a variable collected as specified by
usrHistoryControlEntry.1 and usrHistoryObjectEntry.1.5,
would be named usrHistoryAbsValue.1.14.5"
INDEX { usrHistoryControlIndex, usrHistorySampleIndex,
usrHistoryObjectIndex }
::= { usrHistoryTable 1 }
UsrHistoryEntry ::= SEQUENCE {
usrHistorySampleIndex Integer32,
usrHistoryIntervalStart TimeStamp,
usrHistoryIntervalEnd TimeStamp,
usrHistoryAbsValue Gauge32,
usrHistoryValStatus INTEGER
}
usrHistorySampleIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular sample this
entry represents among all samples associated with the same
usrHistoryControlEntry. This index starts at 1 and increases
by one as each new sample is taken."
::= { usrHistoryEntry 1 }
usrHistoryIntervalStart OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
Waldbusser Standards Track [Page 86]
RFC 2021 Remote Network Monitoring MIB January 1997
DESCRIPTION
"The value of sysUpTime at the start of the interval over
which this sample was measured. If the probe keeps track of
the time of day, it should start the first sample of the
history at a time such that when the next hour of the day
begins, a sample is started at that instant.
Note that following this rule may require the probe to delay
collecting the first sample of the history, as each sample
must be of the same interval. Also note that the sample which
is currently being collected is not accessible in this table
until the end of its interval."
::= { usrHistoryEntry 2 }
usrHistoryIntervalEnd OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the end of the interval over which
this sample was measured."
::= { usrHistoryEntry 3 }
usrHistoryAbsValue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The absolute value (i.e. unsigned value) of the
user-specified statistic during the last sampling period. The
value during the current sampling period is not made available
until the period is completed.
To obtain the true value for this sampling interval, the
associated instance of usrHistoryValStatus must be checked,
and usrHistoryAbsValue adjusted as necessary.
If the MIB instance could not be accessed during the sampling
interval, then this object will have a value of zero and the
associated instance of usrHistoryValStatus will be set to
'valueNotAvailable(1)'."
::= { usrHistoryEntry 4 }
usrHistoryValStatus OBJECT-TYPE
SYNTAX INTEGER {
valueNotAvailable(1),
valuePositive(2),
Waldbusser Standards Track [Page 87]
RFC 2021 Remote Network Monitoring MIB January 1997
valueNegative(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the validity and sign of the data in
the associated instance of usrHistoryAbsValue.
If the MIB instance could not be accessed during the sampling
interval, then 'valueNotAvailable(1)' will be returned.
If the sample is valid and actual value of the sample is
greater than or equal to zero then 'valuePositive(2)' is
returned.
If the sample is valid and the actual value of the sample is
less than zero, 'valueNegative(3)' will be returned. The
associated instance of usrHistoryAbsValue should be multiplied
by -1 to obtain the true sample value."
::= { usrHistoryEntry 5 }
-- The Probe Configuration Group
--
-- This group controls the configuration of various operating
-- parameters of the probe.
ControlString ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used to communicate with a modem or a
serial data switch. A ControlString contains embedded
commands to control how the device will interact with the
remote device through the serial interface. Commands are
represented as two character sequences beginning with
the `^' character.
The following commands are recognized by the device (note
that command characters are case sensitive):
^s Send string that follows which is terminated by the
next command or the end of string.
^c Delay for the number of seconds that follows. Toss
out any data received rather than storing it in a
buffer for parsing.
^t Set timeout to the value represented by the decimal
digits that follow. The default timeout is 20
seconds. Note that this timeout may be overridden
by a smaller serialTimeout configured for the
Waldbusser Standards Track [Page 88]
RFC 2021 Remote Network Monitoring MIB January 1997
associated serial interface (see serialConfigTable).
^w Wait for the reply string that follows which is
terminated by the next command or the end of string.
Partial and case insensitive matching is applied, ie.
if the reply string (any case combination) is found
anywhere in the received string, then the a match is
found. If the current timeout elapses without a match,
then the remaining control string is ignored.
^! The ^ character.
^d Delay the number of seconds specified by the decimal
digits that follow.
^b Send break for the number of milliseconds specified by
the decimal digits that follow. If no digits follow,
break will be enforced for 250 milliseconds by default.
The following ASCII control characters may be inserted into
the `^s' send string or the `^w' reply string:
^@ 0x00
^A 0x01
..
^M 0x0D
..
^Z 0x1A
^[ 0x1B
^ 0x1C
^] 0x1D
^^ 0x1E
^_ 0x1F
Binary data may also be inserted into the data stream. The
control sequence for each byte of binary data is ^0x##, where
## is the hexadecimal representation of the data byte. Two
ASCII characters (0-9, a-f, A-F) must follow the `^0x'
control prefix. For example, `^0x0D^0x0A' is interpreted as a
carriage return followed by a line feed."
SYNTAX DisplayString
probeCapabilities OBJECT-TYPE
SYNTAX BITS {
etherStats(0),
historyControl(1),
etherHistory(2),
alarm(3),
hosts(4),
hostTopN(5),
matrix(6),
filter(7),
Waldbusser Standards Track [Page 89]
RFC 2021 Remote Network Monitoring MIB January 1997
capture(8),
event(9),
tokenRingMLStats(10),
tokenRingPStats(11),
tokenRingMLHistory(12),
tokenRingPHistory(13),
ringStation(14),
ringStationOrder(15),
ringStationConfig(16),
sourceRouting(17),
protocolDirectory(18),
protocolDistribution(19),
addressMapping(20),
nlHost(21),
nlMatrix(22),
alHost(23),
alMatrix(24),
usrHistory(25),
probeConfig(26)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of the RMON MIB groups supported
on at least one interface by this probe."
::= { probeConfig 1 }
probeSoftwareRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software revision of this device. This string will have
a zero length if the revision is unknown."
::= { probeConfig 2 }
probeHardwareRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hardware revision of this device. This string will have
a zero length if the revision is unknown."
::= { probeConfig 3 }
probeDateTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0 | 8 | 11))
MAX-ACCESS read-write
Waldbusser Standards Track [Page 90]
RFC 2021 Remote Network Monitoring MIB January 1997
STATUS current
DESCRIPTION
"Probe's current date and time.
field octets contents range
----- ------ -------- -----
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..60
(use 60 for leap-second)
7 8 deci-seconds 0..9
8 9 direction from UTC '+' / '-'
9 10 hours from UTC 0..11
10 11 minutes from UTC 0..59
For example, Tuesday May 26, 1992 at 1:30:15 PM
EDT would be displayed as:
1992-5-26,13:30:15.0,-4:0
Note that if only local time is known, then
timezone information (fields 8-10) is not
present, and if no time information is known, the null
string is returned."
::= { probeConfig 4 }
probeResetControl OBJECT-TYPE
SYNTAX INTEGER {
running(1),
warmBoot(2),
coldBoot(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to warmBoot(2) causes the device to
restart the application software with current configuration
parameters saved in non-volatile memory. Setting this
object to coldBoot(3) causes the device to reinitialize
configuration parameters in non-volatile memory to default
values and restart the application software. When the device
is running normally, this variable has a value of
running(1)."
::= { probeConfig 5 }
Waldbusser Standards Track [Page 91]
RFC 2021 Remote Network Monitoring MIB January 1997
-- The following download objects do not restrict an implementation
-- from implementing additional download mechanisms (controlled in an
-- implementation-specific manner). Further, in the case where the RMON
-- agent shares a processor with other types of systems, the
-- implementation is not required to download those non-RMON functions
-- with this mechanism.
probeDownloadFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The file name to be downloaded from the TFTP server when a
download is next requested via this MIB. This value is set to
the zero length string when no file name has been specified."
::= { probeConfig 6 }
probeDownloadTFTPServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the TFTP server that contains the boot
image to load when a download is next requested via this MIB.
This value is set to `0.0.0.0' when no IP address has been
specified."
::= { probeConfig 7 }
probeDownloadAction OBJECT-TYPE
SYNTAX INTEGER {
notDownloading(1),
downloadToPROM(2),
downloadToRAM(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to downloadToRAM(2) or
downloadToPROM(3), the device will discontinue its
normal operation and begin download of the image specified
by probeDownloadFile from the server specified by
probeDownloadTFTPServer using the TFTP protocol. If
downloadToRAM(2) is specified, the new image is copied
to RAM only (the old image remains unaltered in the flash
EPROM). If downloadToPROM(3) is specified
the new image is written to the flash EPROM
memory after its checksum has been verified to be correct.
When the download process is completed, the device will
Waldbusser Standards Track [Page 92]
RFC 2021 Remote Network Monitoring MIB January 1997
warm boot to restart the newly loaded application.
When the device is not downloading, this object will have
a value of notDownloading(1)."
::= { probeConfig 8 }
probeDownloadStatus OBJECT-TYPE
SYNTAX INTEGER {
downloadSuccess(1),
downloadStatusUnknown(2),
downloadGeneralError(3),
downloadNoResponseFromServer(4),
downloadChecksumError(5),
downloadIncompatibleImage(6),
downloadTftpFileNotFound(7),
downloadTftpAccessViolation(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the last download procedure, if any. This
object will have a value of downloadStatusUnknown(2) if no
download process has been performed."
::= { probeConfig 9 }
serialConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of serial interface configuration entries. This data
will be stored in non-volatile memory and preserved across
probe resets or power loss."
::= { probeConfig 10 }
serialConfigEntry OBJECT-TYPE
SYNTAX SerialConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of configuration parameters for a particular
serial interface on this device. If the device has no serial
interfaces, this table is empty.
The index is composed of the ifIndex assigned to this serial
line interface."
INDEX { ifIndex }
::= { serialConfigTable 1 }
Waldbusser Standards Track [Page 93]
RFC 2021 Remote Network Monitoring MIB January 1997
SerialConfigEntry ::= SEQUENCE {
serialMode INTEGER,
serialProtocol INTEGER,
serialTimeout Integer32 (1..65535),
serialModemInitString ControlString (SIZE (0..255)),
serialModemHangUpString ControlString (SIZE (0..255)),
serialModemConnectResp DisplayString (SIZE (0..255)),
serialModemNoConnectResp DisplayString (SIZE (0..255)),
serialDialoutTimeout Integer32 (1..65535),
serialStatus RowStatus
}
serialMode OBJECT-TYPE
SYNTAX INTEGER {
direct(1),
modem(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of incoming connection to expect on this serial
interface."
DEFVAL { direct }
::= { serialConfigEntry 1 }
serialProtocol OBJECT-TYPE
SYNTAX INTEGER {
other(1),
slip(2),
ppp(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of data link encapsulation to be used on this
serial interface."
DEFVAL { slip }
::= { serialConfigEntry 2 }
serialTimeout OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This timeout value is used when the Management Station has
initiated the conversation over the serial link. This variable
represents the number of seconds of inactivity allowed before
terminating the connection on this serial interface. Use the
Waldbusser Standards Track [Page 94]
RFC 2021 Remote Network Monitoring MIB January 1997
serialDialoutTimeout in the case where the probe has initiated
the connection for the purpose of sending a trap."
DEFVAL { 300 }
::= { serialConfigEntry 3 }
serialModemInitString OBJECT-TYPE
SYNTAX ControlString (SIZE (0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A control string which controls how a modem attached to this
serial interface should be initialized. The initialization
is performed once during startup and again after each
connection is terminated if the associated serialMode has the
value of modem(2).
A control string that is appropriate for a wide variety of
modems is: '^s^MATE0Q0V1X4 S0=1 S2=43^M'."
::= { serialConfigEntry 4 }
serialModemHangUpString OBJECT-TYPE
SYNTAX ControlString (SIZE (0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A control string which specifies how to disconnect a modem
connection on this serial interface. This object is only
meaningful if the associated serialMode has the value
of modem(2).
A control string that is appropriate for a wide variety of
modems is: '^d2^s+++^d2^sATH0^M^d2'."
::= { serialConfigEntry 5 }
serialModemConnectResp OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An ASCII string containing substrings that describe the
expected modem connection response code and associated bps
rate. The substrings are delimited by the first character
in the string, for example:
/CONNECT/300/CONNECT 1200/1200/CONNECT 2400/2400/
CONNECT 4800/4800/CONNECT 9600/9600
will be interpreted as:
response code bps rate
CONNECT 300
CONNECT 1200 1200
Waldbusser Standards Track [Page 95]
RFC 2021 Remote Network Monitoring MIB January 1997
CONNECT 2400 2400
CONNECT 4800 4800
CONNECT 9600 9600
The agent will use the information in this string to adjust
the bps rate of this serial interface once a modem connection
is established.
A value that is appropriate for a wide variety of modems is:
'/CONNECT/300/CONNECT 1200/1200/CONNECT 2400/2400/
CONNECT 4800/4800/CONNECT 9600/9600/CONNECT 14400/14400/
CONNECT 19200/19200/CONNECT 38400/38400/'."
::= { serialConfigEntry 6 }
serialModemNoConnectResp OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An ASCII string containing response codes that may be
generated by a modem to report the reason why a connection
attempt has failed. The response codes are delimited by
the first character in the string, for example:
/NO CARRIER/BUSY/NO DIALTONE/NO ANSWER/ERROR/
If one of these response codes is received via this serial
interface while attempting to make a modem connection,
the agent will issue the hang up command as specified by
serialModemHangUpString.
A value that is appropriate for a wide variety of modems is:
'/NO CARRIER/BUSY/NO DIALTONE/NO ANSWER/ERROR/'."
::= { serialConfigEntry 7 }
serialDialoutTimeout OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This timeout value is used when the probe initiates the
serial connection with the intention of contacting a
management station. This variable represents the number
of seconds of inactivity allowed before terminating the
connection on this serial interface."
DEFVAL { 20 }
::= { serialConfigEntry 8 }
serialStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
Waldbusser Standards Track [Page 96]
RFC 2021 Remote Network Monitoring MIB January 1997
STATUS current
DESCRIPTION
"The status of this serialConfigEntry.
An entry may not exist in the active state unless all
objects in the entry have an appropriate value."
::= { serialConfigEntry 9 }
netConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF NetConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of netConfigEntries."
::= { probeConfig 11 }
netConfigEntry OBJECT-TYPE
SYNTAX NetConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of configuration parameters for a particular
network interface on this device. If the device has no network
interface, this table is empty.
The index is composed of the ifIndex assigned to the
corresponding interface."
INDEX { ifIndex }
::= { netConfigTable 1 }
NetConfigEntry ::= SEQUENCE {
netConfigIPAddress IpAddress,
netConfigSubnetMask IpAddress,
netConfigStatus RowStatus
}
netConfigIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP address of this Net interface. The default value
for this object is 0.0.0.0. If either the netConfigIPAddress
or netConfigSubnetMask are 0.0.0.0, then when the device
boots, it may use BOOTP to try to figure out what these
values should be. If BOOTP fails, before the device
can talk on the network, this value must be configured
(e.g., through a terminal attached to the device). If BOOTP is
Waldbusser Standards Track [Page 97]
RFC 2021 Remote Network Monitoring MIB January 1997
used, care should be taken to not send BOOTP broadcasts too
frequently and to eventually send very infrequently if no
replies are received."
::= { netConfigEntry 1 }
netConfigSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The subnet mask of this Net interface. The default value
for this object is 0.0.0.0. If either the netConfigIPAddress
or netConfigSubnetMask are 0.0.0.0, then when the device
boots, it may use BOOTP to try to figure out what these
values should be. If BOOTP fails, before the device
can talk on the network, this value must be configured
(e.g., through a terminal attached to the device). If BOOTP is
used, care should be taken to not send BOOTP broadcasts too
frequently and to eventually send very infrequently if no
replies are received."
::= { netConfigEntry 2 }
netConfigStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this netConfigEntry.
An entry may not exist in the active state unless all
objects in the entry have an appropriate value."
::= { netConfigEntry 3 }
netDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP Address of the default gateway. If this value is
undefined or unknown, it shall have the value 0.0.0.0."
::= { probeConfig 12 }
-- Trap Destination Table
--
-- This table defines the destination addresses for traps generated
-- from the device. This table maps a community to one or more trap
-- destination entries.
--
Waldbusser Standards Track [Page 98]
RFC 2021 Remote Network Monitoring MIB January 1997
-- The same trap will be sent to all destinations specified in the
-- entries that have the same trapDestCommunity as the eventCommunity
-- (as defined by RMON MIB). Information in this table will be stored
-- in non-volatile memory. If the device has gone through a hard
-- restart, this information will be reset to its default state.
trapDestTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapDestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of trap destination entries."
::= { probeConfig 13 }
trapDestEntry OBJECT-TYPE
SYNTAX TrapDestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry includes a destination IP address to which to send
traps for this community."
INDEX { trapDestIndex }
::= { trapDestTable 1 }
TrapDestEntry ::= SEQUENCE {
trapDestIndex Integer32,
trapDestCommunity OCTET STRING,
trapDestProtocol INTEGER,
trapDestAddress OCTET STRING,
trapDestOwner OwnerString,
trapDestStatus RowStatus
}
trapDestIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A value that uniquely identifies this trapDestEntry."
::= { trapDestEntry 1 }
trapDestCommunity OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..127))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A community to which this destination address belongs.
This entry is associated with any eventEntries in the RMON
Waldbusser Standards Track [Page 99]
RFC 2021 Remote Network Monitoring MIB January 1997
MIB whose value of eventCommunity is equal to the value of
this object. Every time an associated event entry sends a
trap due to an event, that trap will be sent to each
address in the trapDestTable with a trapDestCommunity equal to
eventCommunity.
This object may not be modified if the associated
trapDestStatus object is equal to active(1)."
::= { trapDestEntry 2 }
trapDestProtocol OBJECT-TYPE
SYNTAX INTEGER {
ip(1),
ipx(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The protocol with which to send this trap."
::= { trapDestEntry 3 }
trapDestAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The address to send traps on behalf of this entry.
If the associated trapDestProtocol object is equal to ip(1),
the encoding of this object is the same as the snmpUDPAddress
textual convention in [RFC1906]:
-- for a SnmpUDPAddress of length 6:
--
-- octets contents encoding
-- 1-4 IP-address network-byte order
-- 5-6 UDP-port network-byte order
If the associated trapDestProtocol object is equal to ipx(2),
the encoding of this object is the same as the snmpIPXAddress
textual convention in [RFC1906]:
-- for a SnmpIPXAddress of length 12:
--
-- octets contents encoding
-- 1-4 network-number network-byte order
-- 5-10 physical-address network-byte order
-- 11-12 socket-number network-byte order
This object may not be modified if the associated
Waldbusser Standards Track [Page 100]
RFC 2021 Remote Network Monitoring MIB January 1997
trapDestStatus object is equal to active(1)."
::= { trapDestEntry 4 }
trapDestOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { trapDestEntry 5 }
trapDestStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this trap destination entry.
An entry may not exist in the active state unless all
objects in the entry have an appropriate value."
::= { trapDestEntry 6 }
-- Serial Connection Table
--
-- The device may communicate with a management station using
-- SLIP. In order for the device to send traps via SLIP, it must
-- be able to initiate a connection over the serial interface. The
-- serialConnectionTable stores the parameters for such connection
-- initiation.
serialConnectionTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialConnectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of serialConnectionEntries."
::= { probeConfig 14 }
serialConnectionEntry OBJECT-TYPE
SYNTAX SerialConnectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration for a SLIP link over a serial line."
INDEX { serialConnectIndex }
::= { serialConnectionTable 1 }
Waldbusser Standards Track [Page 101]
RFC 2021 Remote Network Monitoring MIB January 1997
SerialConnectionEntry ::= SEQUENCE {
serialConnectIndex Integer32,
serialConnectDestIpAddress IpAddress,
serialConnectType INTEGER,
serialConnectDialString ControlString,
serialConnectSwitchConnectSeq ControlString,
serialConnectSwitchDisconnectSeq ControlString,
serialConnectSwitchResetSeq ControlString,
serialConnectOwner OwnerString,
serialConnectStatus RowStatus
}
serialConnectIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A value that uniquely identifies this serialConnection
entry."
::= { serialConnectionEntry 1 }
serialConnectDestIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP Address that can be reached at the other end of this
serial connection.
This object may not be modified if the associated
serialConnectStatus object is equal to active(1)."
::= { serialConnectionEntry 2 }
serialConnectType OBJECT-TYPE
SYNTAX INTEGER {
direct(1),
modem(2),
switch(3),
modemSwitch(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of outgoing connection to make. If this object
has the value direct(1), then a direct serial connection
is assumed. If this object has the value modem(2),
then serialConnectDialString will be used to make a modem
connection. If this object has the value switch(3),
Waldbusser Standards Track [Page 102]
RFC 2021 Remote Network Monitoring MIB January 1997
then serialConnectSwitchConnectSeq will be used to establish
the connection over a serial data switch, and
serialConnectSwitchDisconnectSeq will be used to terminate
the connection. If this object has the value
modem-switch(4), then a modem connection will be made first
followed by the switch connection.
This object may not be modified if the associated
serialConnectStatus object is equal to active(1)."
DEFVAL { direct }
::= { serialConnectionEntry 3 }
serialConnectDialString OBJECT-TYPE
SYNTAX ControlString (SIZE(0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A control string which specifies how to dial the phone
number in order to establish a modem connection. The
string should include dialing prefix and suffix. For
example: ``^s^MATD9,888-1234^M'' will instruct the Probe
to send a carriage return followed by the dialing prefix
``ATD'', the phone number ``9,888-1234'', and a carriage
return as the dialing suffix.
This object may not be modified if the associated
serialConnectStatus object is equal to active(1)."
::= { serialConnectionEntry 4 }
serialConnectSwitchConnectSeq OBJECT-TYPE
SYNTAX ControlString (SIZE(0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A control string which specifies how to establish a
data switch connection.
This object may not be modified if the associated
serialConnectStatus object is equal to active(1)."
::= { serialConnectionEntry 5 }
serialConnectSwitchDisconnectSeq OBJECT-TYPE
SYNTAX ControlString (SIZE(0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A control string which specifies how to terminate a
data switch connection.
This object may not be modified if the associated
Waldbusser Standards Track [Page 103]
RFC 2021 Remote Network Monitoring MIB January 1997
serialConnectStatus object is equal to active(1)."
::= { serialConnectionEntry 6 }
serialConnectSwitchResetSeq OBJECT-TYPE
SYNTAX ControlString (SIZE(0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A control string which specifies how to reset a data
switch in the event of a timeout.
This object may not be modified if the associated
serialConnectStatus object is equal to active(1)."
::= { serialConnectionEntry 7 }
serialConnectOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { serialConnectionEntry 8 }
serialConnectStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this serialConnectionEntry.
If the manager attempts to set this object to active(1) when
the serialConnectType is set to modem(2) or modem-switch(4)
and the serialConnectDialString is a zero-length string or
cannot be correctly parsed as a ConnectString, the set
request will be rejected with badValue(3).
If the manager attempts to set this object to active(1) when
the serialConnectType is set to switch(3) or modem-switch(4)
and the serialConnectSwitchConnectSeq,
the serialConnectSwitchDisconnectSeq, or
the serialConnectSwitchResetSeq are zero-length strings
or cannot be correctly parsed as ConnectStrings, the set
request will be rejected with badValue(3).
An entry may not exist in the active state unless all
objects in the entry have an appropriate value."
::= { serialConnectionEntry 9 }
Waldbusser Standards Track [Page 104]
RFC 2021 Remote Network Monitoring MIB January 1997
--
-- Extensions to the RMON 1 MIB for RMON 2 devices
--
-- These extensions include the standard LastCreateTime Textual
-- Convention for all control tables, as well as an augmentation of
-- the filter entry that provides variable-length offsets into
-- packets.
-- Each of the following, except for filterDroppedFrames, is a
-- read-only object which, if implemented, automatically appears when
-- the RMON1 row it is associated with is created.
etherStats2Table OBJECT-TYPE
SYNTAX SEQUENCE OF EtherStats2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
::= { statistics 4 }
etherStats2Entry OBJECT-TYPE
SYNTAX EtherStats2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
AUGMENTS { etherStatsEntry }
::= { etherStats2Table 1 }
EtherStats2Entry ::= SEQUENCE {
etherStatsDroppedFrames Counter32,
etherStatsCreateTime LastCreateTime
}
etherStatsDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
is out of some resources and decides to shed load from this
collection.
This count does not include packets that were not counted
Waldbusser Standards Track [Page 105]
RFC 2021 Remote Network Monitoring MIB January 1997
because they had MAC-layer errors.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { etherStats2Entry 1 }
etherStatsCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this control entry was last
activated. This can be used by the management station to
ensure that the table has not been deleted and recreated
between polls."
::= { etherStats2Entry 2 }
historyControl2Table OBJECT-TYPE
SYNTAX SEQUENCE OF HistoryControl2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
::= { history 5 }
historyControl2Entry OBJECT-TYPE
SYNTAX HistoryControl2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
AUGMENTS { historyControlEntry }
::= { historyControl2Table 1 }
HistoryControl2Entry ::= SEQUENCE {
historyControlDroppedFrames Counter32
}
historyControlDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
is out of some resources and decides to shed load from this
Waldbusser Standards Track [Page 106]
RFC 2021 Remote Network Monitoring MIB January 1997
collection.
This count does not include packets that were not counted
because they had MAC-layer errors.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { historyControl2Entry 1 }
hostControl2Table OBJECT-TYPE
SYNTAX SEQUENCE OF HostControl2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
::= { hosts 4 }
hostControl2Entry OBJECT-TYPE
SYNTAX HostControl2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
AUGMENTS { hostControlEntry }
::= { hostControl2Table 1 }
HostControl2Entry ::= SEQUENCE {
hostControlDroppedFrames Counter32,
hostControlCreateTime LastCreateTime
}
hostControlDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
is out of some resources and decides to shed load from this
collection.
This count does not include packets that were not counted
because they had MAC-layer errors.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
Waldbusser Standards Track [Page 107]
RFC 2021 Remote Network Monitoring MIB January 1997
::= { hostControl2Entry 1 }
hostControlCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this control entry was last
activated. This can be used by the management station to
ensure that the table has not been deleted and recreated
between polls."
::= { hostControl2Entry 2 }
matrixControl2Table OBJECT-TYPE
SYNTAX SEQUENCE OF MatrixControl2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
::= { matrix 4 }
matrixControl2Entry OBJECT-TYPE
SYNTAX MatrixControl2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
AUGMENTS { matrixControlEntry }
::= { matrixControl2Table 1 }
MatrixControl2Entry ::= SEQUENCE {
matrixControlDroppedFrames Counter32,
matrixControlCreateTime LastCreateTime
}
matrixControlDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
is out of some resources and decides to shed load from this
collection.
This count does not include packets that were not counted
Waldbusser Standards Track [Page 108]
RFC 2021 Remote Network Monitoring MIB January 1997
because they had MAC-layer errors.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { matrixControl2Entry 1 }
matrixControlCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this control entry was last
activated. This can be used by the management station to
ensure that the table has not been deleted and recreated
between polls."
::= { matrixControl2Entry 2 }
channel2Table OBJECT-TYPE
SYNTAX SEQUENCE OF Channel2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
::= { filter 3 }
channel2Entry OBJECT-TYPE
SYNTAX Channel2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
AUGMENTS { channelEntry }
::= { channel2Table 1 }
Channel2Entry ::= SEQUENCE {
channelDroppedFrames Counter32,
channelCreateTime LastCreateTime
}
channelDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
Waldbusser Standards Track [Page 109]
RFC 2021 Remote Network Monitoring MIB January 1997
is out of some resources and decides to shed load from this
collection.
This count does not include packets that were not counted
because they had MAC-layer errors.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { channel2Entry 1 }
channelCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this control entry was last
activated. This can be used by the management station to
ensure that the table has not been deleted and recreated
between polls."
::= { channel2Entry 2 }
tokenRingMLStats2Table OBJECT-TYPE
SYNTAX SEQUENCE OF TokenRingMLStats2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
::= { statistics 5 }
tokenRingMLStats2Entry OBJECT-TYPE
SYNTAX TokenRingMLStats2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
AUGMENTS { tokenRingMLStatsEntry }
::= { tokenRingMLStats2Table 1 }
TokenRingMLStats2Entry ::= SEQUENCE {
tokenRingMLStatsDroppedFrames Counter32,
tokenRingMLStatsCreateTime LastCreateTime
}
tokenRingMLStatsDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Waldbusser Standards Track [Page 110]
RFC 2021 Remote Network Monitoring MIB January 1997
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
is out of some resources and decides to shed load from this
collection.
This count does not include packets that were not counted
because they had MAC-layer errors.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { tokenRingMLStats2Entry 1 }
tokenRingMLStatsCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this control entry was last activated.
This can be used by the management station to ensure that the
table has not been deleted and recreated between polls."
::= { tokenRingMLStats2Entry 2 }
tokenRingPStats2Table OBJECT-TYPE
SYNTAX SEQUENCE OF TokenRingPStats2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
::= { statistics 6 }
tokenRingPStats2Entry OBJECT-TYPE
SYNTAX TokenRingPStats2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
AUGMENTS { tokenRingPStatsEntry }
::= { tokenRingPStats2Table 1 }
TokenRingPStats2Entry ::= SEQUENCE {
tokenRingPStatsDroppedFrames Counter32,
tokenRingPStatsCreateTime LastCreateTime
}
tokenRingPStatsDroppedFrames OBJECT-TYPE
SYNTAX Counter32
Waldbusser Standards Track [Page 111]
RFC 2021 Remote Network Monitoring MIB January 1997
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
is out of some resources and decides to shed load from this
collection.
This count does not include packets that were not counted
because they had MAC-layer errors.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { tokenRingPStats2Entry 1 }
tokenRingPStatsCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this control entry was last activated.
This can be used by the management station to ensure that the
table has not been deleted and recreated between polls."
::= { tokenRingPStats2Entry 2 }
ringStationControl2Table OBJECT-TYPE
SYNTAX SEQUENCE OF RingStationControl2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
::= { tokenRing 7 }
ringStationControl2Entry OBJECT-TYPE
SYNTAX RingStationControl2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
AUGMENTS { ringStationControlEntry }
::= { ringStationControl2Table 1 }
RingStationControl2Entry ::= SEQUENCE {
ringStationControlDroppedFrames Counter32,
ringStationControlCreateTime LastCreateTime
}
Waldbusser Standards Track [Page 112]
RFC 2021 Remote Network Monitoring MIB January 1997
ringStationControlDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
is out of some resources and decides to shed load from this
collection.
This count does not include packets that were not counted
because they had MAC-layer errors.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { ringStationControl2Entry 1 }
ringStationControlCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this control entry was last activated.
This can be used by the management station to ensure that the
table has not been deleted and recreated between polls."
::= { ringStationControl2Entry 2 }
sourceRoutingStats2Table OBJECT-TYPE
SYNTAX SEQUENCE OF SourceRoutingStats2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
::= { tokenRing 8 }
sourceRoutingStats2Entry OBJECT-TYPE
SYNTAX SourceRoutingStats2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the RMON-2 augmentations to RMON-1."
AUGMENTS { sourceRoutingStatsEntry }
::= { sourceRoutingStats2Table 1 }
SourceRoutingStats2Entry ::= SEQUENCE {
sourceRoutingStatsDroppedFrames Counter32,
Waldbusser Standards Track [Page 113]
RFC 2021 Remote Network Monitoring MIB January 1997
sourceRoutingStatsCreateTime LastCreateTime
}
sourceRoutingStatsDroppedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames which were received by the probe
and therefore not accounted for in the *StatsDropEvents, but
for which the probe chose not to count for this entry for
whatever reason. Most often, this event occurs when the probe
is out of some resources and decides to shed load from this
collection.
This count does not include packets that were not counted
because they had MAC-layer errors.
Note that, unlike the dropEvents counter, this number is the
exact number of frames dropped."
::= { sourceRoutingStats2Entry 1 }
sourceRoutingStatsCreateTime OBJECT-TYPE
SYNTAX LastCreateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this control entry was last activated.
This can be used by the management station to ensure that the
table has not been deleted and recreated between polls."
::= { sourceRoutingStats2Entry 2 }
filter2Table OBJECT-TYPE
SYNTAX SEQUENCE OF Filter2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provides a variable-length packet filter feature to the
RMON-1 filter table."
::= { filter 4 }
filter2Entry OBJECT-TYPE
SYNTAX Filter2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Provides a variable-length packet filter feature to the
RMON-1 filter table."
Waldbusser Standards Track [Page 114]
RFC 2021 Remote Network Monitoring MIB January 1997
AUGMENTS { filterEntry }
::= { filter2Table 1 }
Filter2Entry ::= SEQUENCE {
filterProtocolDirDataLocalIndex Integer32,
filterProtocolDirLocalIndex Integer32
}
filterProtocolDirDataLocalIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When this object is set to a non-zero value, the filter that
it is associated with performs the following operations on
every packet:
1) - If the packet doesn't match the protocol directory entry
identified by this object, discard the packet and exit
(i.e., discard the packet if it is not of the identified
protocol).
2) - If the associated filterProtocolDirLocalIndex is non-zero
and the packet doesn't match the protocol directory
entry identified by that object, discard the packet and
exit
3) - If the packet matches, perform the regular filter
algorithm as if the beginning of this named protocol is
the beginning of the packet, potentially applying the
filterOffset value to move further into the packet."
DEFVAL { 0 }
::= { filter2Entry 1 }
filterProtocolDirLocalIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When this object is set to a non-zero value, the filter that
it is associated with will discard the packet if the packet
doesn't match this protocol directory entry."
DEFVAL { 0 }
::= { filter2Entry 2 }
-- Conformance Macros
rmon2MIBCompliances OBJECT IDENTIFIER ::= { rmonConformance 1 }
rmon2MIBGroups OBJECT IDENTIFIER ::= { rmonConformance 2 }
Waldbusser Standards Track [Page 115]
RFC 2021 Remote Network Monitoring MIB January 1997
rmon2MIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to
the RMON2 MIB"
MODULE -- this module
MANDATORY-GROUPS { protocolDirectoryGroup,
protocolDistributionGroup,
addressMapGroup,
nlHostGroup,
nlMatrixGroup,
usrHistoryGroup,
probeInformationGroup }
GROUP rmon1EnhancementGroup
DESCRIPTION
"The rmon1EnhancementGroup is mandatory for systems which
implement RMON [RFC1757]"
::= { rmon2MIBCompliances 1 }
rmon2MIBApplicationLayerCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to
the RMON2 MIB with Application Layer Enhancements."
MODULE -- this module
MANDATORY-GROUPS { protocolDirectoryGroup,
protocolDistributionGroup,
addressMapGroup,
nlHostGroup,
nlMatrixGroup,
alHostGroup,
alMatrixGroup,
usrHistoryGroup,
probeInformationGroup }
GROUP rmon1EnhancementGroup
DESCRIPTION
"The rmon1EnhancementGroup is mandatory for systems which
implement RMON [RFC1757]"
::= { rmon2MIBCompliances 2 }
protocolDirectoryGroup OBJECT-GROUP
OBJECTS { protocolDirLastChange,
protocolDirLocalIndex, protocolDirDescr,
protocolDirType, protocolDirAddressMapConfig,
protocolDirHostConfig, protocolDirMatrixConfig,
Waldbusser Standards Track [Page 116]
RFC 2021 Remote Network Monitoring MIB January 1997
protocolDirOwner, protocolDirStatus }
STATUS current
DESCRIPTION
"Lists the inventory of protocols the probe has the capability
of monitoring and allows the addition, deletion, and
configuration of entries in this list."
::= { rmon2MIBGroups 1 }
protocolDistributionGroup OBJECT-GROUP
OBJECTS { protocolDistControlDataSource,
protocolDistControlDroppedFrames,
protocolDistControlCreateTime,
protocolDistControlOwner, protocolDistControlStatus,
protocolDistStatsPkts, protocolDistStatsOctets }
STATUS current
DESCRIPTION
"Collects the relative amounts of octets and packets for the
different protocols detected on a network segment."
::= { rmon2MIBGroups 2 }
addressMapGroup OBJECT-GROUP
OBJECTS { addressMapInserts, addressMapDeletes,
addressMapMaxDesiredEntries,
addressMapControlDataSource,
addressMapControlDroppedFrames,
addressMapControlOwner, addressMapControlStatus,
addressMapPhysicalAddress,
addressMapLastChange }
STATUS current
DESCRIPTION
"Lists MAC address to network address bindings discovered by
the probe and what interface they were last seen on."
::= { rmon2MIBGroups 3 }
nlHostGroup OBJECT-GROUP
OBJECTS { hlHostControlDataSource,
hlHostControlNlDroppedFrames, hlHostControlNlInserts,
hlHostControlNlDeletes,
hlHostControlNlMaxDesiredEntries,
hlHostControlAlDroppedFrames, hlHostControlAlInserts,
hlHostControlAlDeletes,
hlHostControlAlMaxDesiredEntries, hlHostControlOwner,
hlHostControlStatus, nlHostInPkts, nlHostOutPkts,
nlHostInOctets, nlHostOutOctets,
nlHostOutMacNonUnicastPkts, nlHostCreateTime }
STATUS current
DESCRIPTION
"Counts the amount of traffic sent from and to each network
Waldbusser Standards Track [Page 117]
RFC 2021 Remote Network Monitoring MIB January 1997
address discovered by the probe. Note that while the
hlHostControlTable also has objects that control an optional
alHostTable, implementation of the alHostTable is not required
to fully implement this group."
::= { rmon2MIBGroups 4 }
nlMatrixGroup OBJECT-GROUP
OBJECTS { hlMatrixControlDataSource,
hlMatrixControlNlDroppedFrames,
hlMatrixControlNlInserts, hlMatrixControlNlDeletes,
hlMatrixControlNlMaxDesiredEntries,
hlMatrixControlAlDroppedFrames,
hlMatrixControlAlInserts, hlMatrixControlAlDeletes,
hlMatrixControlAlMaxDesiredEntries,
hlMatrixControlOwner, hlMatrixControlStatus,
nlMatrixSDPkts, nlMatrixSDOctets, nlMatrixSDCreateTime,
nlMatrixDSPkts, nlMatrixDSOctets, nlMatrixDSCreateTime,
nlMatrixTopNControlMatrixIndex,
nlMatrixTopNControlRateBase,
nlMatrixTopNControlTimeRemaining,
nlMatrixTopNControlGeneratedReports,
nlMatrixTopNControlDuration,
nlMatrixTopNControlRequestedSize,
nlMatrixTopNControlGrantedSize,
nlMatrixTopNControlStartTime,
nlMatrixTopNControlOwner, nlMatrixTopNControlStatus,
nlMatrixTopNProtocolDirLocalIndex,
nlMatrixTopNSourceAddress, nlMatrixTopNDestAddress,
nlMatrixTopNPktRate, nlMatrixTopNReversePktRate,
nlMatrixTopNOctetRate, nlMatrixTopNReverseOctetRate }
STATUS current
DESCRIPTION
"Counts the amount of traffic sent between each pair of
network addresses discovered by the probe. Note that while the
hlMatrixControlTable also has objects that control optional
alMatrixTables, implementation of the alMatrixTables is not
required to fully implement this group."
::= { rmon2MIBGroups 5 }
alHostGroup OBJECT-GROUP
OBJECTS { alHostInPkts, alHostOutPkts,
alHostInOctets, alHostOutOctets, alHostCreateTime }
STATUS current
DESCRIPTION
"Counts the amount of traffic, by protocol, sent from and to
each network address discovered by the probe. Implementation
of this group requires implementation of the Network Layer
Host Group."
Waldbusser Standards Track [Page 118]
RFC 2021 Remote Network Monitoring MIB January 1997
::= { rmon2MIBGroups 6 }
alMatrixGroup OBJECT-GROUP
OBJECTS { alMatrixSDPkts, alMatrixSDOctets, alMatrixSDCreateTime,
alMatrixDSPkts, alMatrixDSOctets, alMatrixDSCreateTime,
alMatrixTopNControlMatrixIndex,
alMatrixTopNControlRateBase,
alMatrixTopNControlTimeRemaining,
alMatrixTopNControlGeneratedReports,
alMatrixTopNControlDuration,
alMatrixTopNControlRequestedSize,
alMatrixTopNControlGrantedSize,
alMatrixTopNControlStartTime,
alMatrixTopNControlOwner, alMatrixTopNControlStatus,
alMatrixTopNProtocolDirLocalIndex,
alMatrixTopNSourceAddress, alMatrixTopNDestAddress,
alMatrixTopNAppProtocolDirLocalIndex,
alMatrixTopNPktRate, alMatrixTopNReversePktRate,
alMatrixTopNOctetRate, alMatrixTopNReverseOctetRate }
STATUS current
DESCRIPTION
"Counts the amount of traffic, by protocol, sent between each
pair of network addresses discovered by the
probe. Implementation of this group requires implementation of
the Network Layer Matrix Group."
::= { rmon2MIBGroups 7 }
usrHistoryGroup OBJECT-GROUP
OBJECTS { usrHistoryControlObjects,
usrHistoryControlBucketsRequested,
usrHistoryControlBucketsGranted,
usrHistoryControlInterval,
usrHistoryControlOwner, usrHistoryControlStatus,
usrHistoryObjectVariable, usrHistoryObjectSampleType,
usrHistoryIntervalStart, usrHistoryIntervalEnd,
usrHistoryAbsValue, usrHistoryValStatus }
STATUS current
DESCRIPTION
"The usrHistoryGroup provides user-defined collection of
historical information from MIB objects on the probe."
::= { rmon2MIBGroups 8 }
probeInformationGroup OBJECT-GROUP
OBJECTS { probeCapabilities,
probeSoftwareRev, probeHardwareRev, probeDateTime }
STATUS current
DESCRIPTION
"This group describes various operating parameters of the
Waldbusser Standards Track [Page 119]
RFC 2021 Remote Network Monitoring MIB January 1997
probe as well as controlling the local time of the probe."
::= { rmon2MIBGroups 9 }
probeConfigurationGroup OBJECT-GROUP
OBJECTS { probeResetControl, probeDownloadFile,
probeDownloadTFTPServer, probeDownloadAction,
probeDownloadStatus,
serialMode, serialProtocol, serialTimeout,
serialModemInitString, serialModemHangUpString,
serialModemConnectResp, serialModemNoConnectResp,
serialDialoutTimeout, serialStatus,
netConfigIPAddress, netConfigSubnetMask,
netConfigStatus, netDefaultGateway,
trapDestCommunity, trapDestProtocol, trapDestAddress,
trapDestOwner, trapDestStatus,
serialConnectDestIpAddress, serialConnectType,
serialConnectDialString, serialConnectSwitchConnectSeq,
serialConnectSwitchDisconnectSeq,
serialConnectSwitchResetSeq,
serialConnectOwner, serialConnectStatus }
STATUS current
DESCRIPTION
"This group controls the configuration of various operating
parameters of the probe."
::= { rmon2MIBGroups 10 }
rmon1EnhancementGroup OBJECT-GROUP
OBJECTS { historyControlDroppedFrames, hostControlDroppedFrames,
hostControlCreateTime, matrixControlDroppedFrames,
matrixControlCreateTime, channelDroppedFrames,
channelCreateTime, filterProtocolDirDataLocalIndex,
filterProtocolDirLocalIndex }
STATUS current
DESCRIPTION
"This group adds some enhancements to RMON-1 that help
management stations."
::= { rmon2MIBGroups 11 }
rmon1EthernetEnhancementGroup OBJECT-GROUP
OBJECTS { etherStatsDroppedFrames, etherStatsCreateTime }
STATUS current
DESCRIPTION
"This group adds some enhancements to RMON-1 that help
management stations."
::= { rmon2MIBGroups 12 }
rmon1TokenRingEnhancementGroup OBJECT-GROUP
OBJECTS { tokenRingMLStatsDroppedFrames,
Waldbusser Standards Track [Page 120]
RFC 2021 Remote Network Monitoring MIB January 1997
tokenRingMLStatsCreateTime,
tokenRingPStatsDroppedFrames, tokenRingPStatsCreateTime,
ringStationControlDroppedFrames,
ringStationControlCreateTime,
sourceRoutingStatsDroppedFrames,
sourceRoutingStatsCreateTime }
STATUS current
DESCRIPTION
"This group adds some enhancements to RMON-1 that help
management stations."
::= { rmon2MIBGroups 13 }
END
Waldbusser Standards Track [Page 121]
RFC 2021 Remote Network Monitoring MIB January 1997
7. Security Considerations
In order to implement this MIB, a probe must capture all packets on
the locally-attached network, including packets between third
parties. These packets are analyzed to collect network addresses,
protocol usage information, and conversation statistics. Data of this
nature may be considered sensitive in some environments. In such
environments the administrator may wish to restrict SNMP access to
the probe.
A probe implementing this MIB is likely to also implement RMON
[RFC1757], which includes functions for returning the contents of
captured packets, potentially including sensitive user data or
passwords. It is recommended that SNMP access to these functions be
restricted.
Waldbusser Standards Track [Page 122]
RFC 2021 Remote Network Monitoring MIB January 1997
8. Appendix - TimeFilter Implementation Notes
1) Theory of Operation
The TimeFilter mechanism allows an NMS to reduce the number of SNMP
transactions required for a 'table-update' operation. Polling of
tables that incorporate a 'TimeFilter' INDEX can be reduced to a
theoretical minimum (if used correctly). It can be easily implemented
by an agent in a way independent of the number of NMS applications
using the same time-filtered table.
Although the name 'TimeFilter' may imply that a history of change
events is maintained by the agent, this is not the case. A time-
filtered-value represents the current value of the object instance,
not the 'saved' value at the time indicated by the TimeFilter INDEX
value. Note that TimeFilter objects only appear in INDEX clauses
(always not-accessible), so their value is never retrieved. By
design, the actual value of a TimeFilter instance is not in itself
meaningful (it's not a 'last-change-timestamp').
The TimeFilter is a boolean filtering function applied in internal
Get* PDU processing. If the 'last-change-time' of the specified
instance is less than the particular TimeFilter INDEX value, then the
instance is considered 'not-present' (skipped for GetNext and GetBulk
PDUs; 'noSuchInstance' or returned to the requester.
1.1) Agent Implementation of a Time-Filtered Table
In implementation, the time-filtered rows (one for each tick of
sysUpTime) are only conceptual. The agent simply filters a real table
based on:
* the current value of sysUpTime
* the TimeFilter value passed in the varbind
* the last-update timestamp of each requested counter
(agent implementation requirement)
For example, to implement a time-filtered counter, an agent maintains
a timestamp in a 32-bit storage location, initialized to zero. This
is in addition to whatever instrumentation is needed for the counter.
Each time the counter is updated, the current value of sysUpTime is
recorded in the associated timestamp. If this is not possible or
practical, then a background polling process must 'refresh' the
timestamp by sampling counter values and comparing them to recorded
samples. The timestamp update must occur within 5 seconds of the
actual change event.
Waldbusser Standards Track [Page 123]
RFC 2021 Remote Network Monitoring MIB January 1997
When an agent receives a Get, GetNext, or GetBulk PDU requesting a
time-filtered instance, the following agent has determined that the
instance is within the MIB view indicated by the community string in
the PDU.
/* return TRUE if the object is present */
boolean time_filter_test (
TimeFilter last_modified_timestamp,
TimeFilter index_value_in_pdu )
{
if (last_modified_timestamp < index_value_in_pdu)
return FALSE;
else
return TRUE;
}
The agent applies this function regardless of the lastActivationTime
of the conceptual row in question. In other words, counter
discontinuities are ignored (i.e. conceptual row deleted and then
re-created later). An agent should consider a object instance
'changed' when it is created (either at restart time for scalars and
static objects, or row-creation-time for dynamic tables).
Note that using a timeFilter INDEX value of zero removes the
filtering functionality, as the instance will always be
1.2) NMS Implementation of a Time-Filtered Table
The particular TimeFilter INDEX values used by an NMS reflect the
polling interval of the NMS, relative to the particular agent's
notion of sysUpTime.
An NMS needs to maintain one timestamp variable per agent
(initialized to zero) for an arbitrary group of time-filtered MIB
objects that are gathered together in the same PDU. Each time the
Get* PDU is sent, a request for sysUpTime is included. The retrieved
sysUpTime value is used as the timeFilter value in the next polling
cycle. If a polling sweep of a time-filtered group of objects
requires more than one SNMP transaction, then the sysUpTime value
retrieved in the first GetResponse PDU of the polling sweep is saved
as the next timeFilter value.
The actual last-update time of a given object is not indicated in the
returned GetResponse instance identifier, but rather the timeFilter
value passed in the Get*Request PDU is returned.
Waldbusser Standards Track [Page 124]
RFC 2021 Remote Network Monitoring MIB January 1997
A "time-filtered get-next/bulk-sweep", done once per polling
cycle, is a series of GetNext or GetBulk transactions, and is
over when one of the following events occurs:
1) the TimeFilter index value returned in the GetResponse is
different than the TimeFilter index value passed in the
GetNext or GetBulk request. Counter values will still be
returned beyond this point (until the last-change-time is
reached), but most likely the same values will be
returned.
2) the return PDU includes instances lexigraphically greater
than the objects expected (i.e. same GetNext semantics as
if the TimeFilter wasn't there)
3) a noSuchName or other exception/error is returned.
Note that the use of a time-filtered table in combination with a
GetRequest PDU neutralizes any optimization that otherwise might be
achieved with the TimeFilter, because no PDU transactions are saved.
Either the current time-filtered object-value is returned, or a
'noSuchInstance' exception (SNMPv1c) or 'noSuchName' error (SNMPv1)
is returned.
If GetBulk PDUs are used, then the value selected for response PDUs
generated by the agent, since duplicate entries (one per size. An
appropriate of conceptual rows in the time-filtered table if known, or
equal to the number of instances expected to fit in a GetResponse PDU
without causing a 'tooBig' error from the agent.
2) TimeFilter Example
The following example demonstrates how an NMS and Agent might use a
table with a TimeFilter object in the INDEX. A static table is
assumed to keep the example simple, but dynamic tables can also be
supported.
2.1) General Assumptions
fooEntry INDEX { fooTimeMark, fooIfIndex }
FooEntry = SEQUENCE {
fooTimeMark TimeFilter,
fooIfIndex Integer32,
fooCounts Counter32
}
The NMS polls the fooTable every 15 seconds and the
baseline
poll occurs when the agent has been up for 6 seconds,
and the NMS has been up for 10 seconds.
Waldbusser Standards Track [Page 125]
RFC 2021 Remote Network Monitoring MIB January 1997
There are 2 static rows in this table at system
initialization
(fooCounts.0.1 and fooCounts.0.2).
Row 1 was updated as follows:
SysUpTime fooCounts.*.1 value 500
1 900 2
2300 3
Row 2 was updated as follows:
SysUpTime fooCounts.*.2 value
1100 1
1400 2
2.2) SNMP Transactions from NMS Perspective
Time nms-1000:
# NMS baseline poll -- get everything since last agent
restart
# TimeFilter == 0
get-bulk(nonRptrs=1, maxReps=2, sysUpTime.0,
fooCounts.0);
returns:
sysUpTime.0 == 600
fooCounts.0.1 == 1 # incremented at time 500
fooCounts.0.2 == 0 # visible since created at time 0
Time nms-2500:
# NMS 1st poll
# TimeFilter index == 600
get-bulk(nonRptrs=1, maxReps=2, sysUpTime.0,
fooCounts.600);
returns:
sysUpTime.0 == 2100
fooCounts.600.1 == 2 # incremented at time 900
fooCounts.600.2 == 2 # incremented at times 1100 and
1400
fooCounts.601.1 == 2 # indicates end of sweep
Waldbusser Standards Track [Page 126]
RFC 2021 Remote Network Monitoring MIB January 1997
Time nms-4000:
# NMS 2nd poll
# TimeFilter == 2100
get-bulk(nonRptrs=1, maxReps=2, sysUpTime.0,
fooCounts.2100);
returns:
sysUpTime.0 == 3600
fooCounts.2100.1 == 3 # incremented at time 2300
fooCounts.2102.1 == 3 # indicates end-of-sweep
# the counter value for row 2 is not returned because
# it hasn't changed since sysUpTime == 2100.
# The next timetick value for row 1 is returned instead
Time nms-5500:
# NMS 3rd poll
# TimeFilter == 3600
get-bulk(nonRptrs=1, maxReps=2, sysUpTime.0,
fooCounts.3600);
returns:
sysUpTime.0 == 5100
some-instance-outside-the-fooTable == <don't care>
some-instance-outside-the-fooTable == <don't care>
# no 'fooTable' counter values at all are returned
because
# neither counter has been updated since sysUpTime ==
3600
2.3) Transactions and TimeFilter Maintenance: Agent
Perspective
Time agt-0:
# initialize fooTable
fooCounts.1 = 0; changed.1 = 0;
fooCounts.2 = 0; changed.2 = 0;
Time agt-500:
# increment fooCounts.1
++fooCounts.1; changed.1 = 500;
Waldbusser Standards Track [Page 127]
RFC 2021 Remote Network Monitoring MIB January 1997
Time agt-600
# answer get-bulk
# get-bulk(nonRptrs=1, maxReps=2, sysUpTime.0,
# fooCounts.0);
# (changed >= 0)
# return both counters
Time agt-900:
# increment fooCounts.1
++fooCounts.1; changed.1 = 900;
Time agt-1100:
# increment fooCounts.2
++fooCounts.2; changed.2 = 1100;
Time agt-1400:
# increment fooCounts.2
++fooCounts.2; changed.2 = 1400;
Time agt-2100
# answer get-bulk
# get-bulk(nonRptrs=1, maxReps=2, sysUpTime.0,
# fooCounts.600);
# (changed >= 600)
# return both counters
Time agt-2300:
# increment fooCounts.1
++fooCounts.1; changed.1 = 2300;
Time agt-3600:
# answer get-bulk
# get-bulk(nonRptrs=1, maxReps=2, sysUpTime.0,
# fooCounts.2100);
# (changed >= 2100)
# return only fooCounts.1 from the fooTable--twice
Time agt-5100:
# answer get-bulk
# get-bulk(nonRptrs=1, maxReps=2, sysUpTime.0,
# fooCounts.3600);
# (changed >= 3600)
# return lexigraphically-next two MIB instances
Waldbusser Standards Track [Page 128]
RFC 2021 Remote Network Monitoring MIB January 1997
9. Acknowledgments
This document was produced by the IETF Remote Network Monitoring
Working Group.
10. References
[1] SNMPv2 Working Group, J. Case, K. McCloghrie, M. Rose, S.
Waldbusser, "Structure and Identification of Management
Information for Version 2 of the Simple Network
Management Protocol (SNMPv2)" RFC 1902, January 1996.
[2] SNMPv2 Working Group, J. Case, K. McCloghrie, M. Rose, S.
Waldbusser, "Textual Conventions for Version 2 of the
Simple Network Management Protocol (SNMPv2)", RFC 1903
January 1996.
[3] McCloghrie, K., and M. Rose, "Management Information Base
for Network Management of TCP/IP-based internets: MIB-II",
STD 17, RFC 1213, March 1991.
[4] SNMPv2 Working Group, J. Case, K. McCloghrie, M. Rose, S.
Waldbusser, "Protocol Operations for version 2 of the
Simple Network Management Protocol (SNMPv2)",
RFC 1905, January 1996.
[5] McCloghrie, K., and F. Kastenholz, "Evolution of the
Interfaces Group of MIB-II", RFC 1573, January 1994.
[6] Information processing systems -- Open Systems
Interconnection -- Specification of Abstract Syntax
Notation One (ASN.1), International Organization for
Standardization. International Standard 8824, (December,
1987).
[7] Information processing systems -- Open Systems
Interconnection -- Specification of Basic Encoding Rules
for Abstract Notation One (ASN.1), International
Organization for Standardization. International Standard
8825, (December, 1987).
[8] Rose, M., Editor, "A Convention for Defining Traps for
use with the SNMP", RFC 1215, March 1991.
[9] Waldbusser, S., "Remote Network Monitoring Management
Information Base", RFC 1757, February 1995.
Waldbusser Standards Track [Page 129]
RFC 2021 Remote Network Monitoring MIB January 1997
[10] Waldbusser, S., "Token Ring Extensions to the Remote Network
Monitoring MIB", RFC 1513, September 1993.
11. Author's Address
Steven Waldbusser
International Network Services
Phone: (415) 254-4251
EMail: waldbusser@ins.com
Waldbusser Standards Track [Page 130]